Week 8 HW: Microbial Manufacturing
Overview
This week moved from designing reactions to manufacturing a biofilm — a surface-attached community of bacteria held together in a matrix they secrete themselves. The class is building a shared library of biofilms grown to one protocol so that they can later be used to test therapeutics, and the reason that library is needed is a manufacturing problem rather than a biological one: there is no standardised way of producing these films, so when a treatment appears to work on one biofilm and fail on another, nobody can say whether the treatment changed or the biofilm did [2].
Every participant holds the protocol constant and varies exactly one thing. I varied the substrate — the material the biofilm is grown on.
Nothing here has been measured. Every predicted direction below is a hypothesis, and I am not affiliated with a wet lab, so the experiment would be run at William & Mary [1].
| Assignment component | Status |
|---|---|
| Sign-up sheet: variable and rationale | Complete |
| Part 1: experiment to control heterogeneity | Complete |
| Part 2: a technique beyond crystal violet | Complete |
Timing, for the record: proposals were due on the shared sheet by 17 November, collected through a form completed by node leaders, with the intention of running the experiment the same week [3].
The organism and the system
The organism is Mycobacterium smegmatis. It is a BSL-1 soil and water organism, not a pathogen — as Margaret Saha put it, dig a shovelful of garden soil and you have probably breathed in thousands of them [2]. It is used here as a safe stand-in for the mycobacteria that matter clinically.
The system is deliberately boring so that one variable can stand out: a flat-bottom 96-well plate, one plate type, controlled temperature, careful attention to evaporation in the wells, imaging every 12 to 24 hours for about four days, and quantification by crystal violet [2]. Samples are spread across the plate rather than clustered together, because there are edge effects on plates [2]. The detailed working method the node has converged on — inoculum optical density, volumes per well, humidified incubation and a 3–5 day maturation window — is the one written into the shared sign-up sheet [12].
My variable: a surface that disappears
Everyone else’s substrate on the shared sheet is permanent — polystyrene, silicone, titanium alloy. Nobody is testing a material designed to be consumed.
That is the gap I chose. Bioresorbable polyesters are used in orthopaedics precisely that way, and are applied as coatings onto titanium implants specifically to reduce biofilm formation in early infection [4]. So a surface that degrades underneath the biofilm is not an exotic idea — it is a material already going into people, and asking how biofilm behaves on it is a real question rather than a novelty.
It is also a change of question. Every other substrate on the sheet asks does slime stick to this? Mine asks what happens when the surface itself is going away?
The design
Four conditions, four replicates each, medium held constant throughout.
| ID | Substrate | What it isolates |
|---|---|---|
| PS-REF | Bare polystyrene well bottom, no disc | Shared baseline with the rest of the class |
| PET-INERT | Poly(ethylene terephthalate) disc | A polyester of the same geometry that does not degrade |
| PHB-AR | Poly(3-hydroxybutyrate) disc, as received | Degradable, carrying residual fermentation material |
| PHB-CL | The same PHB, additionally cleaned | Degradable, residue reduced |
Each pair is chosen so one comparison means one thing. PHB-CL against PET-INERT isolates degradability at matched disc geometry. PHB-AR against PHB-CL isolates what is left on the surface from manufacturing. PS-REF ties my plate back to everyone else’s.
All four disc types receive the same ethanol sterilisation, so that sterilisation is not itself an accidental second variable.
Hypothesis, in two parts
Degradability. PHB is biodegradable, and soil bacteria secrete enzymes that erode PHB films from the surface — one soil isolate removed 98.7% of a PHB film in five days, with the erosion confirmed directly by electron microscopy [5]. M. smegmatis is itself a soil organism, and this assay runs three to five days: the same timescale. So the PHB disc may act not only as something to attach to but as a slowly released local food source.
I predict PHB will differ from PET, and I deliberately do not predict the direction. A surface that feeds the biofilm could produce more biomass. A surface that erodes out from under it could shed biofilm and produce patchier, less reproducible wells. Whether M. smegmatis specifically can depolymerise PHB is the thing I could not settle from the literature, and that uncertainty is the point of running it.
Purity. Colonisation of this polymer family turns out to depend less on the polymer than on how clean it is: purified material supported biofilm at or below the level of ordinary polystyrene, while residual protein and lipopolysaccharide left over from fermentation increased biofilm formation, apparently by giving bacteria something to attach to [6]. I therefore predict PHB-AR will exceed PHB-CL. A chemically modified version of the same polymer family reduced staphylococcal biofilm more than threefold against control polyesters while initial adhesion was unchanged [7], which suggests these surfaces act on how the biofilm develops rather than only on whether cells first stick.
One expectation across all three polymers: the mycobacterial cell envelope is unusually lipid-rich and water-repelling, and on biomaterials generally it is hydrophobicity rather than roughness that dominates biofilm formation [8]. So I expect all three polymer surfaces to be colonised readily, and the differences between them — not the fact of colonisation — to carry the information.
Why I chose this, beyond the class
My final project proposes manufacturing PHB from coal-mine methane. In that project I treat leftover endotoxin as a safety question: will the material irritate skin. The purity result above says the same residue is also a performance question — it changes how readily the material is colonised. That is an argument I am importing into my proposal, and I want to be precise that this experiment would not test my own material: it uses commercial PHB, not methane-derived polymer, and M. smegmatis has nothing to do with where my material ends up.
Part 1: an experiment to control heterogeneity
Biofilms are heterogeneous in two different ways, and conflating them is why “make it more reproducible” is usually vague. They need different responses.
Between-well heterogeneity is a manufacturing defect: nominally identical wells give different answers. Within-biofilm heterogeneity is real biology — cells deep inside a film are oxygen-starved, slow-growing and physiologically unlike the cells on top, and the same genotype behaves very differently depending on where it sits [2]. The first should be removed. The second cannot be, and should be measured instead.
The specific thing I would attack
Mycobacteria clump. Non-tuberculous mycobacteria aggregate spontaneously and constitutively, and that aggregation is under metabolic control — cells grow as aggregates when carbon is plentiful and as free-floating cells when carbon is scarce relative to nitrogen, and the balance can be tuned deliberately in defined medium [9].
This matters for our protocol specifically. The method written into the shared sign-up sheet washes the detergent Tween-80 out of the culture before inoculation and resuspends the cells in Tween-free medium [12]. But Tween-80 is routinely added to mycobacterial growth media in the first place precisely because it reduces aggregation [13]. So the wash that the biofilm assay requires also removes the thing that was holding the cells apart. The step that makes the assay work is the same step that allows the inoculum to become uneven. If some wells receive a clump and others receive single cells, the wells have not started from the same place, and no amount of careful incubation afterwards will repair that.
There is a second place the inoculum is decided, upstream of all of this. In the wet-lab session the strain is first grown overnight in standard 7H9 medium rather than directly in biofilm medium, and the reason given was explicit: you do not want it forming biofilms while you are making the glycerol stock [3]. So every well in the class traces back through a pre-culture step whose own state — how long, how dense, how clumped — sits upstream of the variable each of us is testing.
The experiment
Split one inoculum in two. Half is seeded as the protocol prescribes. The other half is aggregate-depleted first — by letting clumps settle and drawing from the top, or passing the suspension through a filter that retains clumps and lets single cells through. Everything after that is identical, and both arms are dispensed by the OT-2 so that pipetting is not an extra variable [2].
The key move is the outcome measure. The primary result is not the mean amount of biofilm. It is the coefficient of variation across replicate wells — the spread divided by the average. Running eight replicates per arm, the question becomes: does removing clumps from the inoculum narrow the distribution?
That reframes reproducibility as something measured rather than assumed, which is the language a manufacturing process needs. A protocol that yields a lower coefficient of variation is a better manufacturing protocol even if it produces less biofilm.
Two supporting controls, both cheap: randomise which wells get which condition so that plate position cannot align with treatment, which addresses the edge effects described in class [2]; and keep the perimeter wells filled with sterile water, as several of the node’s sign-up entries already specify [12], so that evaporation — which Saha singled out as something to be careful about in a 96-well dish [2] — is not read as biology.
And for the heterogeneity that cannot be removed, the honest answer is to stop treating it as noise and image it — which is Part 2.
Part 2: a technique beyond crystal violet
Crystal violet is a positively charged dye. It sticks to anything negatively charged, which is most of a biofilm, and the amount retained after washing is read as “how much biofilm”. Its limits were stated plainly in class [2]:
- It binds all negatively charged surfaces, so it is biased against a positively charged biofilm.
- It stains dead cells as readily as live ones.
- It returns one number for total biomass: no composition, no structure, no information about where anything is.
There is a fourth limit that matters for my experiment in particular. If my PHB disc gives a lower reading than PET, crystal violet alone cannot tell me whether less biofilm grew or whether biofilm grew and then detached as the surface eroded beneath it. Those are opposite conclusions from the same number.
What I propose: confocal microscopy with live/dead staining, quantified
Confocal laser scanning microscopy optically slices through an intact biofilm, so the film can be reconstructed in three dimensions rather than dissolved into a single absorbance value. Combined with a stain that distinguishes intact from compromised cells, and analysed with the standard quantification package for biofilm image stacks, it returns biovolume, mean thickness, surface roughness and the spatial distribution of living against dead cells [10]. The current version of that analysis also quantifies extracellular DNA within the architecture [11], which is one of the structural components of the matrix described in class [2].
This answers exactly what crystal violet cannot: it separates “less biofilm” from “biofilm that left”, it reports structure rather than bulk, and it measures the within-biofilm heterogeneity from Part 1 instead of averaging it away.
Two cheaper additions
A metabolic-activity read in the same plate reader, using a dye that is converted only by respiring cells. It reports live biomass where crystal violet reports all biomass, so the two bracket the truth from opposite sides. It costs one extra plate read.
Electron microscopy of the disc itself at the end of the run. This is specific to my experiment: surface erosion of a degrading PHB film is directly visible this way, and it is how erosion was confirmed in the degradation study I am relying on [5]. If the PHB surface is pitted and the PET surface is not, I have independent evidence that degradation actually happened during the experiment rather than being assumed.
A third option, tying back to the measurement session earlier in the course: mass spectrometry of the extracted matrix, which addresses the question posed there as the most critical of the three — not just did I make the right thing and how much of it, but is there anything else in there.
What I am uncertain about
- Whether M. smegmatis can degrade PHB at all. I could not find this established. If it cannot, PHB becomes simply another hydrophobic polyester surface and the degradability half of my hypothesis collapses into the purity half.
- The exact cleaning step for PHB-CL. It must remove surface protein and endotoxin without restructuring the polymer surface, and I would want William & Mary’s view before fixing it.
- Whether a loose disc moves during handling and washing. If it does, that is a reproducibility problem of my own making, and the honest fix is to report it rather than to exclude those wells.
References
HTBAA Homework: Mycobacteria biofilms, assignment brief, Fall 2026.
HTBAA class, 10 November 2026, lecture by Margaret Saha (William & Mary). Points cited are from the automatic transcript.
HTBAA recitation and wet lab, 12 November 2026. Points cited are from the automatic transcript.
Zermeño-Pérez, Chouirfa, Rodriguez and colleagues (2024), Bioresorbable polyester coatings with antifouling and antimicrobial properties for prevention of biofilm formation in early stage infections on Ti6Al4V hard-tissue implants, ACS Applied Bio Materials. doi:10.1021/acsabm.4c00832 · PubMed
Jeon, Jin, Kong and colleagues (2023), Poly(3-hydroxybutyrate) degradation by a soil isolate and identification of strains expressing PHB depolymerase, Journal of Microbiology and Biotechnology. doi:10.4014/jmb.2303.03013 · PubMed
Mauclaire, Brombacher, Bünger and Zinn (2009), Factors controlling bacterial attachment and biofilm formation on medium-chain-length polyhydroxyalkanoates (mcl-PHAs), Colloids and Surfaces B: Biointerfaces. doi:10.1016/j.colsurfb.2009.10.021 · PubMed
Dinjaski, Fernández-Gutiérrez, Selvam and colleagues (2013), PHACOS, a functionalized bacterial polyester with bactericidal activity against methicillin-resistant Staphylococcus aureus, Biomaterials. doi:10.1016/j.biomaterials.2013.09.059 · PubMed
De-la-Pinta, Cobos, Ibarretxe and colleagues (2019), Effect of biomaterials hydrophobicity and roughness on biofilm development, Journal of Materials Science: Materials in Medicine. doi:10.1007/s10856-019-6281-3 · PubMed
DePas, Bergkessel and Newman (2019), Aggregation of non-tuberculous mycobacteria is regulated by carbon–nitrogen balance, mBio. doi:10.1128/mBio.01715-19 · PubMed
Heydorn, Nielsen, Hentzer and colleagues (2000), Quantification of biofilm structures by the novel computer program COMSTAT, Microbiology. PubMed
Gomes, Ribeiro, Carvalho and colleagues (2023), Quantification of extracellular DNA in biofilm architecture using confocal microscopy and COMSTAT 2, Indian Journal of Microbiology. PubMed
HTBAA shared sign-up sheet, Microbial Manufacturing (261110), as circulated 16 November 2026. The working method — base medium composition, Tween-free inoculum at OD₆₀₀ ≈ 0.7, 67 µL into 133 µL per well, humidified incubation with water-filled perimeter wells, 3–5 day maturation — is recorded there by participants, not in the class recordings.
Pietersen and du Preez (2019), Tween 80 induces a carbon flux rerouting in Mycobacterium tuberculosis, Journal of Microbiological Methods. Cited here only for the stated reason Tween 80 is routinely added to mycobacterial growth media — to increase growth rate and reduce aggregation. PubMed
Use of AI
I used Claude (claude-opus-5) to read the class recordings, search the literature and draft this page, which I then edited. Two things are worth recording because they changed the outcome.
It first recommended varying calcium in the medium, on the reasoning that I already understood calcium crosslinking from my own material work. When I supplied the shared sign-up sheet, calcium turned out to already be claimed by someone in my own node — so the recommendation was wrong, and only checking what others had claimed caught it.
It also initially described the PHA substrate idea as testing my own project material. It is not: it uses commercial PHB and a soil organism unrelated to my project’s end use. It corrected that itself when I asked what the experiment was actually for, and the honest version of the connection — an argument I can borrow, not a measurement I would make — is the one written above.