Week 7 HW: Analytical Tools and Mass Spectrometry
Measuring What Is Actually There
Page status, 10 November 2026. Early draft. One direction is set out below. The four homework questions are still to be answered.
Participation note. I am taking this course as a Committed Listener, joining from London through the William and Mary node, so I did not attend the instrument tour in person. The answers below describing the mass spectrometry instruments are written from the course material. Everything concerning my own project, sample and measurement questions is my own. I would welcome hands-on access to these instruments when the opportunity arises.
The assignment
The task reflects on the analytical tools used in the course so far and integrates the learnings from the analytical module.
Every analyser shares four components: a mechanism to introduce the sample, a mechanism to probe it using physiochemical properties of the target analytes, a mechanism to detect the probed response, and a mechanism to analyse the data. The module introduced liquid chromatography and mass spectrometry as tools for quantifying and characterising the structure of large and small molecules.
The lab section toured five instruments with five different capabilities: BioAccord, TQ Absolute, Xevo QTOF, Cyclic IMS and CDMS.
The direction I want to develop
My project has reached a point where its central question is a measurement question.
Living Inkblot for Bees proposes a bacterial cellulose pellicle carrying a spatial pattern. Everything in the design so far concerns making that pattern. Almost nothing in it concerns proving the pattern exists.
The verification routes I have considered to date report that something is present. Fluorescence says a signal is emitted. Reflectance says light returns at certain wavelengths. Neither identifies the molecule producing the signal, and neither shows where in the material it sits.
Desorption ElectroSpray Ionization on the Cyclic IMS answers both at once. The instrument records mass-to-charge spectra as a function of position, generating an image of ion intensities. A patterned pellicle placed under DESI would return a map showing which molecule is present at which coordinate.
This matters to the project in a specific way. A bilateral pattern can fail in several ways that look identical from the outside. The compound may have diffused through the hydrated matrix and lost its edges. It may have been produced where intended and then migrated during drying. The visible pattern may come from something other than the molecule I think is making it. A spatial mass spectrometry image separates those cases, where an optical measurement collapses them into one ambiguous result.
The ion mobility dimension adds something further. Cyclic IMS probes secondary and tertiary structure, so a protein deposited in the matrix could be examined for whether it survived in a folded state, in place of only confirming its mass.
What this still needs
Sample format is the open question, and question 3d asks it directly. A hydrated cellulose pellicle is mostly water and holds a dense polymer network. Whether it can be presented to a DESI source as it is, dried first, sectioned, or mounted on a particular substrate is something I need to establish. Drying is the part I am least sure about, since the pattern I want to image may move during exactly the preparation step that makes imaging possible.
1. An analytical tool I have already used
2. Liquid chromatography mass spectrometry
3. Two instruments from the lab
Written from the course material, as noted at the top of this page.
Cyclic IMS
Second instrument
4. One instrument applied to the final project
References
Use of AI
This page describes a proposed analytical approach. No measurements have been performed.