Week 8 LAB: Bacterial Cell Manufacturing
HTBAA Homework #8: Mycobacterial Biofilm Manufacturing
Overview
In this assignment I proposed one variable for the William & Mary experiment on Mycobacterium smegmatis biofilms and I answered two questions about the quality of that experiment: how to control the heterogeneity of biofilms and which measurement could complement the crystal violet stain. The goal of the experiment is a library of reproducible, consistent biofilms that can later be used to test phages and antibiotics [1]. I am in the William & Mary node and I have not run any experiment myself, so this is a proposal for the virtual experiment that the protocol allows, with its rationale.
Part 1: The variable I proposed
I chose the substrate, which the protocol lists as one of the two manufacturing inputs, together with the growth medium [1]. The medium is held constant in every well. I submitted two entries to the class spreadsheet:
| Entry | Substrate | Medium |
|---|---|---|
| 1 (control) | Borosilicate glass coverslip, cut to fit flat on the bottom of a 96-well plate well (about 6 mm in diameter) | Complete biofilm medium from the protocol, unchanged |
| 2 | Borosilicate glass coverslip (or as an alternative, a quartz substrate) with gold structures: a 1.5 nm nickel adhesion layer and gold of 200 nm design thickness, with a 64 µm period | Complete biofilm medium from the protocol, unchanged |
The inoculum is the one in the protocol: 67 µL of culture (OD600 about 0.7) plus 133 µL of medium, 200 µL per well, incubated for 3 to 5 days [1].
Why this variable. The protocol asks how strongly the surface determines attachment and final biofilm biomass [1]. Surface properties such as hydrophobicity influence how microbes attach, although they are not the only factor [2]. Svensson et al. (2014) found that smooth and nanostructured gold gave different Staphylococcus epidermidis biofilms, so the shape of a gold surface can change attachment [3]. Comparing glass with and without gold structures isolates the effect of the structured gold, because it is the same glass and only the gold changes. The base geometry of the structures follows Wang et al. (2023), who used gold resonators on a quartz substrate in a terahertz sensor [4]; I work with borosilicate glass and leave both options.
Hypothesis and prediction. Glass with gold structures will give a different amount of biofilm than bare glass. By analogy with Svensson et al. [3], I would expect less biofilm on the structured surface, but this has not been tested in M. smegmatis.
Part 2: An experiment to control the heterogeneity of biofilms
Biofilms are heterogeneous: Cells inside them live in different chemical conditions and in different physiological states [5]. The protocol also notes that small differences in surface, medium, inoculum handling and maturation can change the result, so the first analytical goal is reproducibility [1]. I propose a reproducibility run that tests how much of the variation comes from the process and not from the condition.
What I would do
Prepare one inoculum for the whole plate. Measure the OD of one culture, adjust it once and dispense it from the same tube, with the OT-2 or manually, so every well receives the same cells.
Randomize the plate map. Replicates of each condition are spread over the plate instead of grouped, so that position effects can be detected [1]. The map is saved as part of the manufacturing record.
Handle edge wells on purpose. Edge wells behave differently from the rest of the plate [6]. I would fill the unused and perimeter wells with sterile medium and incubate the plate in a humid location, as the protocol recommends [1].
Include controls on every plate. A medium-only blank (no cells), a bacteria-plus-medium reference and the class reference surface (standard polystyrene wells) next to my two conditions.
Report the variation, not only the average. For each condition I would give the mean and the spread across the replicates of one plate (within-plate) and across the two independent runs (between-run). I would decide the acceptable level of variation before looking at the data.
What it would tell me. If the replicates of the same condition look alike and the two runs agree, the condition is reproducible and can become a member of the library. If the variation is large, I would look first at position effects on the plate map, then at the inoculum and last at the surface itself.
Part 3: A technique to complement crystal violet
What crystal violet does and does not tell me. The protocol states that the crystal violet result is a measure of attached biomass and not of viability [1]. In class, Margaret also pointed out that the dye is positively charged, so it binds to negatively charged material, may under-detect biofilms that are positively charged and stains dead cells as well. I would therefore add a measurement that does not rely on a dye.
My proposal: A label-free terahertz measurement on the gold-structure chips. The gold structures in Entry 2 are resonators: their response to terahertz light changes when material sits on top of them. Wang et al. (2023) used this principle to distinguish four cell types, with a frequency shift and a change in transmission, without a label and their measurements were done in a dry environment [4]. A review of terahertz metamaterials in biosensing describes the same principle [7].
How I would use it: Measure the transmission of each chip before inoculation as a baseline and again after incubation. The resonance frequency shift and the change in transmission would show how much material the biofilm adds and the same chip can be followed over time, since no staining is needed.
What it adds: A measurement without dye, without the washes that can remove biofilm and with the same sample followed in time.
Limits: It does not tell live cells from dead cells. Water absorbs terahertz light strongly, so the chip would be measured after the medium is removed and the biofilm is dry, which can change the biofilm. The structured area of my chips is small compared with the whole chip. I have not measured the terahertz response of my structures with any biological sample; in my own work I have only seen human cells on similar structures under the microscope without staining, so adhesion and wash retention are still to be tested.
A complement: Live/dead staining with confocal microscopy. To cover the main limit, I would stain a subset of wells with a live/dead stain and image them. This shows how thick the biofilm is and which fraction of the cells is alive. Fluorescent viability staining has been used to compare biofilms on gold surfaces [3]. Its limit is that it needs a confocal microscope and metal surfaces can reflect light.
| Crystal violet | Terahertz (my proposal) | Live/dead + confocal | |
|---|---|---|---|
| What it tells me | Attached biomass [1] | Material added on the chip | Thickness and live/dead fraction |
| Needs a dye | Yes | No | Yes |
| Keeps the sample | No | Yes, same chip over time | No |
| Main limit | Not viability; may bias the result | Water; not live/dead | Instrument; reflection from metal |
AI Usage
I used Claude as a study and drafting assistant for this homework. Claude explained the protocol and the class discussion, helped me compare my options and check my data against my own work and the cited articles,
References
- William & Mary node (HTBAA). Mycobacterial Biofilm Manufacturing: A reproducible platform for rigorous phage and antibiotic testing, HTBAA Homework #8 protocol (2026). It adapts Ojha, A. K., Jacobs, W. R. & Hatfull, G. F. (2015). Genetic dissection of mycobacterial biofilms. In Mycobacteria Protocols, Methods in Molecular Biology 1285. https://doi.org/10.1007/978-1-4939-2450-9_12
- Krasowska, A. & Sigler, K. (2014). How microorganisms use hydrophobicity and what does this mean for human needs? Frontiers in Cellular and Infection Microbiology 4, 112. https://doi.org/10.3389/fcimb.2014.00112
- Svensson, S. et al. (2014). Role of nanostructured gold surfaces on monocyte activation and Staphylococcus epidermidis biofilm formation. International Journal of Nanomedicine 9, 775–794. https://doi.org/10.2147/IJN.S51465
- Wang, P. et al. (2023). An ultra-sensitive metasurface biosensor for instant cancer detection based on terahertz spectra. Nano Research 16, 7304–7311. https://doi.org/10.1007/s12274-023-5386-7
- Stewart, P. S. & Franklin, M. J. (2008). Physiological heterogeneity in biofilms. Nature Reviews Microbiology 6, 199–210. https://doi.org/10.1038/nrmicro1838
- Lundholt, B. K., Scudder, K. M. & Pagliaro, L. (2003). A simple technique for reducing edge effect in cell-based assays. Journal of Biomolecular Screening 8, 566–570.
- Zhang, W. et al. (2023). Terahertz metamaterials for biosensing applications: a review. Biosensors 14(1), 3. https://doi.org/10.3390/bios14010003