Week 7 HW: Measurement & Assays
1. Describe one analytical tool used in class: Plate reader (OD600)
a. How is the sample introduced? The sample is introduced by pipetting a liquid sample into the wells of a microplate. For bacterial growth measurements, a culture can be placed into a transparent 96-well plate, allowing the instrument to measure the sample without manually transferring it into a separate cuvette.
b. What physicochemical property is being leveraged?
The instrument uses the interaction of light with the sample. For OD600 measurements, light scattering by bacterial cells reduces the amount of light transmitted through the sample at a wavelength of 600 nm. The resulting optical density provides an indirect indication of bacterial concentration.
c. What does this allow you to measure?
It allows us to monitor bacterial growth and compare growth between different samples or experimental conditions. By taking repeated measurements over time, we can generate a growth curve and compare how quickly different cultures increase in optical density.
d. How is the output signal detected?
A light source directs light through the sample, and a detector measures the transmitted light. The instrument compares this measurement with a blank reference and reports the result as optical density.
e. What limitations does the tool have?
A plate reader provides a bulk measurement rather than information about the spatial distribution of cells. It cannot distinguish between living and dead cells, and the relationship between optical density and cell concentration is not always linear, especially at high cell densities. Bubbles, suspended particles, and colored components in the medium can also affect measurements.
2. For a liquid chromatography–mass spectrometry (LC-MS) instrument
a. How is the sample introduced into the LC? Into the MS?
The sample is first prepared in a solvent compatible with the liquid chromatography system and introduced into the LC, usually through an autosampler. The liquid mobile phase carries the sample through a column, where its different components are separated.
After separation, the compounds leave the LC column and enter the mass spectrometer through an ionization source. In a typical LC-MS setup, electrospray ionization (ESI) converts molecules in the liquid flow into gas-phase ions. The specific ionization method depends on the instrument configuration.
b. What physicochemical properties are being leveraged?
LC-MS combines two different types of separation.
Liquid chromatography separates compounds according to their interactions with the column and mobile phase. Depending on the column, this can involve differences in hydrophobicity, charge-related properties, or molecular size.
Mass spectrometry then separates and detects ionized compounds according to their mass-to-charge ratio (m/z).
c. What does this allow you to measure?
LC-MS allows us to separate components of a complex mixture and obtain information about their molecular masses and relative abundances. It can be used for identifying compounds, characterizing proteins, investigating post-translational modifications, and quantifying specific molecules.
The LC separation is particularly useful because it reduces interference from other compounds in the sample before the molecules reach the mass spectrometer.
d. How is the output signal detected?
The mass spectrometer detects the ions and records their signal intensity.
The results can be displayed as:
- A mass spectrum, showing signal intensity against mass-to-charge ratio (m/z).
- A chromatogram, showing ion intensity against retention time as compounds leave the LC column. Together, these outputs provide information about which ions are present, their masses, and when they were detected.
e. What limitations does the tool have?
LC-MS requires appropriate sample preparation and compounds that can be separated and ionized under the selected conditions. Complex sample matrices can interfere with measurements or suppress ionization, while compounds with similar masses may be difficult to distinguish without additional analysis.
Another limitation is that detecting a molecule does not automatically establish its biological activity or function. Additional experiments may be needed to confirm its identity or understand its role. The quality of the sample also matters: impurities and interfering compounds can reduce the reliability of the results. These principles connect to the analytical module’s explanation of chromatography, ion separation, and mass-based detection.
3. Choose two mass spectrometry instruments from the lab
I chose the TQ Absolute and the Cyclic IMS because they offer complementary approaches that could be useful for investigating the chemistry behind the patterns in Factory of Mistakes.
Instrument 1 — TQ Absolute Specialization: Protein and peptide quantitation, especially trace analytes. The TQ Absolute is designed for highly sensitive and robust quantification of compounds that are already known. It uses two quadrupoles to select ions with particular mass-to-charge ratios.
a. What makes the instrument unique?
Its main advantage is targeted quantification. Unlike an instrument that generates a broad mass spectrum for characterization, the TQ Absolute is designed to measure specific analytes with high sensitivity and reproducibility across many injections. The important limitation is that the user must already know which analytes they want to measure.
b. What does the output data look like?
The output is an ion chromatogram: a plot showing the intensity of a selected ion over time. The instrument does not generate a conventional full mass spectrum for this measurement. Instead, it monitors selected ions throughout the chromatographic run.
c. What could I measure for this class or my project?
For Factory of Mistakes, I could use the TQ Absolute to quantify a previously identified nutrient or metabolic compound in samples collected from different regions of a bacterial pattern.
For example, I could compare the concentration of a specific nutrient remaining in areas with different bacterial growth patterns. This could help me investigate whether differences in nutrient availability are associated with the visual variations produced by the bacteria. This would be particularly relevant because my project investigates how environmental conditions influence the patterns generated by a living system.
d. What sample format would be needed?
For this application, I would need a prepared and clarified small-molecule extract compatible with LC-MS. The target compound would need to be identified beforehand, and an appropriate reference standard would be needed for quantitative measurement. Since this experiment would focus on small molecules rather than protein structure, native, denatured, or digested protein formats would not directly apply.
Instrument 2 — Cyclic IMS Specialization: Molecular structure, ion mobility, and spatial imaging. The Cyclic IMS is a QTOF mass spectrometer incorporating a cyclic ion-mobility device into its flight path. This adds another dimension to the analysis, allowing molecules to be investigated based on their mobility as well as their mass-to-charge ratios.
a. What makes the instrument unique?
Its most distinctive feature is the integration of ion mobility into the mass spectrometer. This allows it to investigate structural differences between molecules, including aspects of the secondary and tertiary structure of proteins, lipids, and other molecules. It can also accept samples through different introduction methods, including LC, direct injection, and DESI (Desorption Electrospray Ionization). One particularly interesting capability is two-dimensional spatial imaging, which makes it possible to examine the distribution of molecules across a sample.
b. What does the output data look like?
The Cyclic IMS can generate several different types of data:
- A mass spectrum, displaying ion intensity against m/z.
- A chromatogram, showing the signal over time.
- A mobilogram, showing the signal in ion-mobility space.
- A spatial image, showing the intensity of selected ions at different positions in a sample when imaging methods such as DESI are used. The spatial imaging capability is especially interesting for my project because it connects molecular information with the physical location of the sample.
c. What could I measure for this class or my project?
I could investigate the spatial distribution of nutrients or metabolic compounds across a bacterial growth pattern. For example, I could compare the chemical composition of the center, edges, and branching regions of a bacterial pattern. Using DESI imaging, I could potentially generate spatial maps of selected molecular signals and compare these maps with photographs of the visible bacterial growth.
This would help me investigate whether the visual differences between patterns are associated with differences in the chemical environment. It could also help me understand whether nutrient distribution and bacterial metabolism are connected to the shapes produced by the living system.
d. What sample format would be needed?
For spatial imaging, I would need to preserve the spatial organization of the sample rather than homogenizing the entire plate into one mixture. The material would need to be prepared in a form compatible with DESI imaging and the instrument’s sample requirements. I would consult the instrument operator about whether agar-based samples are compatible and what preparation is necessary.
I would not use protein digestion for this particular experiment because the objective would be to investigate the spatial distribution of small molecules. For a separate experiment investigating protein tertiary structure, the sample would instead need to preserve the relevant native structure. The instrument’s ion-mobility, chromatographic, mass-spectrometric, and imaging outputs are described in the course handout.
4. How would I use one of these instruments for my final project?
Chosen instrument: Cyclic IMS using DESI spatial imaging.
For my final project, Factory of Mistakes, I want to investigate how a living bacterial system can generate different visual patterns through environmental variation, particularly differences in nutrient distribution.
The Cyclic IMS could provide another layer of information by allowing me to investigate the spatial distribution of molecules across the bacterial pattern.
Sample preparation I would select representative bacterial plates showing different visual patterns and preserve the spatial organization of the agar and bacterial growth. Rather than extracting the entire plate into one mixture, I would prepare the samples for spatial imaging so that the original locations of the different regions remain distinguishable.
I would also include an uninoculated medium control to help identify chemical signals originating from the medium itself rather than the bacteria. The exact agar preparation and sample compatibility would need to be confirmed with the mass spectrometry facility before conducting the experiment.
Generating the data I would use DESI spatial imaging to analyze selected samples using the Cyclic IMS. The instrument would record mass-to-charge signals at different positions across the sample. This would allow me to generate spatial maps showing the distribution of selected molecular signals. I could then compare those maps with photographs of the bacterial patterns to look for relationships between chemical distribution and visual structure.
What would the data tell me?
The results could help me investigate whether different regions of the bacterial pattern have different chemical compositions, and whether these differences are associated with the resulting visual structures. For example, I might find that certain chemical signals are more abundant near the edges of a pattern, or that different generations of selected patterns show different spatial distributions. However, the intensity of a molecular signal alone would not prove the identity or biological function of a compound. I would need appropriate standards and additional confirmation for any important finding.
How would this advance my project?
The main purpose of Factory of Mistakes is to investigate the relationship between environmental conditions, biological variation, and human selection. At the moment, the project mainly focuses on the visible output of the biological system. Using the Cyclic IMS would allow me to investigate what is happening chemically underneath those visible patterns.
This could help me understand why certain patterns emerge under particular conditions, improve the design of future generations, and connect the visual selection process to measurable biological differences. Ultimately, the instrument could help me move beyond simply observing the resulting patterns and toward understanding some of the chemical processes that contribute to their formation. The course handout specifically describes the Cyclic IMS as supporting DESI-based two-dimensional imaging and mapping ion intensities by position.