Week 7 HW

Question 1 – A tool I have worked with: gel electrophoresis

a) How is the sample introduced? The sample is mixed with a loading buffer (containing glycerol or sucrose so it sinks, and a tracking dye so you can see it run) and pipetted by hand into the wells of a gel. For DNA/RNA the gel is agarose; for proteins it is typically a polyacrylamide gel (SDS-PAGE). A molecular-weight ladder is loaded in one lane as a size reference. The gel sits in a tank of running buffer, and an electric field is applied.

b) What physicochemical property is being leveraged?

  • Charge and size. Nucleic acids carry a uniform negative charge (phosphate backbone), so they migrate toward the positive electrode, and the gel matrix acts as a sieve: smaller fragments move faster and farther than larger ones.
  • For SDS-PAGE, the detergent SDS coats proteins with a uniform negative charge and denatures them, so separation depends almost entirely on molecular weight. (Native gels instead separate by charge, size, and shape together.)

c) What does this allow you to measure?

  • The size of DNA/RNA fragments or proteins (by comparing band position with the ladder).
  • Whether a PCR product, plasmid, or restriction digest is the expected size.
  • Rough purity (number of bands) and approximate relative amount (band intensity).
  • For my project: whether a cloned construct (e.g., FAT-1 or Crt gene) has the expected size.

d) How is the output signal detected? Bands are made visible by staining. DNA gels use a fluorescent intercalating dye (e.g., SYBR Safe or ethidium bromide) imaged under blue or UV light; protein gels use Coomassie or silver stain, or fluorescent stains. A gel imager (camera) captures the image, and software can quantify band intensity (densitometry). Proteins can also be transferred to a membrane and detected with antibodies (Western blot).

e) What limitations does the tool have?

  • Low resolution and only approximate sizing; it cannot resolve molecules of very similar size, and it does not give exact mass or sequence.
  • Semi-quantitative at best: staining is nonlinear and saturates, so band intensity is a poor measure of absolute amount.
  • Low sensitivity compared with MS (needs nanograms to micrograms of material).
  • Identifies by size only: a band at the expected size is not proof of identity (needs sequencing, Western blot, or MS).
  • Cannot separate molecules of the same size but different composition (e.g., two proteins with similar mass, or a modified vs. unmodified protein).
  • Low throughput and manual; results depend on gel quality, loading, and running conditions. Stains (ethidium bromide) can be hazardous.
  • Denaturing gels destroy native structure and activity, so they give no information about folding or complexes.

Question 2 – Liquid Chromatography–Mass Spectrometry (LC-MS)

a) How is the sample introduced into the LC? Into the MS?

  • LC: A small volume of liquid sample (typically 1–10 µL, after cleanup/filtration) is injected by an autosampler into a flowing mobile phase that carries it onto the column. A gradient of changing solvent composition (e.g., water → acetonitrile) elutes the analytes.
  • MS: The column eluent flows directly into an ion source (usually electrospray ionization, ESI), where the liquid is nebulized and charged droplets desolvate to produce gas-phase ions. These ions enter the vacuum system through an inlet and are guided into the mass analyzer.

b) What physicochemical properties are leveraged?

  • LC: Differential interaction with the stationary phase; commonly hydrophobicity (reversed-phase C18), but also charge/isoelectric point (ion exchange), or size (SEC).
  • MS: Mass-to-charge ratio (m/z) of ionized molecules, plus fragmentation behaviour in tandem MS (MS/MS), which depends on structure.

c) What does this allow you to measure?

  • Identity and molecular weight of analytes (proteins, peptides, lipids, small molecules).
  • Sequence and modifications via peptide fragmentation.
  • Relative or absolute quantity (peak areas compared with standards).
  • Purity of a sample and the presence of variants or contaminants.

d) How is the output signal detected? After separation by the analyzer (TOF, quadrupole, etc.), ions strike a detector (electron multiplier or microchannel plate) that converts each ion arrival into an electrical pulse, which is digitized. Data are stored as a chromatogram (intensity vs. retention time) and/or a mass spectrum (intensity vs. m/z). Analysis software then performs peak integration, mass deconvolution, database searching, and quantitation.

e) Limitations

  • Samples must be clean and compatible with the LC (no particulates; salts, detergents, and polymers suppress ionization).
  • Ion suppression/matrix effects can distort quantitation, so internal standards (ideally isotope-labelled) are needed.
  • Isomers have identical masses and need chromatographic separation (or ion mobility) to be told apart.
  • Not all molecules ionize equally well; response factors differ.
  • Expensive instruments, requiring expert operation, calibration, and maintenance.
  • Targeted quantitation requires knowing what to look for in advance; untargeted work gives complex data.
  • Throughput is limited by LC run time (minutes per sample).

Question 3 – Two mass spectrometers from the lab tour

Instrument 1: TQ Absolute (tandem quadrupole)

a) What makes it unique? It is built for robust, sensitive, targeted quantitation of trace analytes over thousands of injections. Two quadrupoles filter ions by m/z, one selecting the parent ion and the second selecting a specific fragment, giving very high selectivity and low background. It is used for clinical samples and for drug/metabolite quantitation (DMPK).

b) What does the output data look like? Not a full mass spectrum. The output is an ion chromatogram, intensity vs. retention time, for each selected transition (MRM/SRM). Peak area is proportional to analyte amount.

c) What could I measure for this class/project?

  • Absolute quantity of β-carotene in engineered vs. unmodified bovine cells, to learn whether the CrtB/CrtI/CrtY pathway works and how much accumulates.
  • Individual fatty acids (ALA, EPA, DHA and their omega-6 counterparts such as LA and AA) to determine the omega-3/omega-6 ratio and confirm FAT-1 activity.
  • A signature peptide of FAT-1 (using heavy-labelled peptide standards) to quantify FAT-1 protein expression. These measurements would tell me whether the engineering achieved its nutritional goal and how much protein expression is needed for it.

d) Required sample format?

  • Digested for protein quantitation (denature, reduce, alkylate, trypsin digest, desalt) with spiked heavy-labelled peptides.
  • Extracted lipids for fatty acids and β-carotene (see Question 4). No native folding is needed.
  • Spike in internal standards, centrifuge/filter, and prepare a calibration curve in a similar matrix.

Instrument 2: BioAccord (LC + TOF)

a) What makes it unique? It is an easy-to-operate, LC-integrated benchtop TOF system with self-diagnostics, designed for routine characterization (protein identity, intact mass, sequence confirmation) and process-analytical work in pharma. It is lower in sensitivity than the QTOF or TQ, but robust and accessible for non-expert users.

b) What does the output data look like? Full mass spectra (m/z vs. intensity), deconvoluted to intact masses, and extracted ion chromatograms (EIC) for individual ions over time.

c) What could I measure for this class/project?

  • Confirm expression of FAT-1 and Crt enzymes by peptide mapping (peptide-level sequence coverage from a digest) or intact mass of a purified protein.
  • Check the identity and purity of any recombinant protein or growth factor used in the medium (e.g., FGF2) and see whether it is intact.
  • Monitor muscle proteins (e.g., myosin or actin peptides) to confirm differentiation. This would tell me whether the engineered cells are expressing the intended proteins and still forming muscle.

d) Required sample format?

  • Digested (trypsin) for peptide mapping of cell lysates, or denatured (acidified, LC compatible) for intact protein analysis of purified proteins.
  • Lysis (with an MS-compatible detergent or detergent removal), clean-up/desalting (e.g., C18 tips), and a sample concentration appropriate for the lower sensitivity of this instrument.

Question 4 – Using mass spectrometry in my final project (Cultivated Beef)

What I want to learn

My project proposes engineering bovine muscle progenitor cells with (1) the FAT-1 desaturase to raise omega-3 relative to omega-6 fatty acids and (2) a CrtB/CrtI/CrtY pathway to make β-carotene. My key biological assumption is that these pathways can work without hurting cell growth or differentiation, and that β-carotene will protect the more oxidation-prone PUFAs. I need a quantitative, specific readout to check each of these.

Instrument choice

The main instrument is the TQ Absolute (LC-MS/MS) for targeted quantitation of fatty acids, β-carotene, and the FAT-1 signature peptide. The BioAccord is a secondary tool for confirming protein expression and differentiation markers.

Sample preparation

  1. Culture and harvest. Grow engineered and unmodified (control) bovine cells in parallel under identical conditions, in replicates, at several time points (proliferation and after differentiation). Count cells so results can be normalized per cell number or per mg protein. Wash with PBS to remove medium lipids and carry-over, pellet, and snap-freeze.
  2. Split each pellet into a lipid fraction and a protein fraction.
  3. Lipids/β-carotene. Add isotope-labelled internal standards (e.g., deuterated fatty acids; β-carotene-d8 where available) and extract with a Folch or Bligh–Dyer solvent system, or hexane/ethyl acetate for carotenoids. Add an antioxidant (BHT) and work under dim light and cold conditions, because both PUFAs and carotenoids degrade easily. Dry under nitrogen and reconstitute in an LC-compatible solvent. For total fatty acids, saponify to release free fatty acids from the complex lipids.
  4. Protein for FAT-1. Lyse, quantify protein, denature, reduce, alkylate, digest with trypsin, and desalt. Spike in heavy-labelled FAT-1 signature peptides.
  5. Calibration and QC. Build calibration curves from pure standards (ALA, EPA, DHA, LA, AA, β-carotene), and include blanks and pooled QC samples run throughout the batch.

Generating the data

  • Fatty acids: Reversed-phase LC (C18) with ESI in negative mode. A good gradient is essential, because omega-3 and omega-6 isomers share the same mass (e.g., ALA vs. GLA) and must be separated chromatographically.
  • β-carotene: A C18 or C30 column with APCI (or ESI) in positive mode, monitoring the parent mass (m/z ≈ 536) and a characteristic fragment, with transitions optimized on a standard.
  • FAT-1 peptide: A standard bottom-up LC-MS/MS MRM method with transitions for the light (endogenous) and heavy (standard) peptide.
  • Data are collected as ion chromatograms for each transition; peak areas are normalized to the internal standards and converted to concentration via the calibration curves.

What the data would tell me

  • Omega-3/omega-6 ratio and absolute fatty-acid levels: whether FAT-1 works in bovine cells, and whether more enzymes (elongases/desaturases) are needed to get EPA/DHA.
  • β-carotene concentration: whether the three-gene pathway functions and accumulates enough to matter nutritionally and as an antioxidant.
  • FAT-1 peptide abundance vs. product output: which expression level gives a useful phenotype without excess burden, directly addressing my “metabolic burden” uncertainty.
  • Engineered vs. control cells: side-by-side data on whether fatty-acid and pigment changes come with reduced growth or differentiation (combined with cell counts and BioAccord data on muscle proteins).
  • Over time (storage/cooking): lipid oxidation products or declining PUFA levels, to test whether β-carotene protects the product.

How it advances the project

These measurements would let me screen engineered cell lines quantitatively instead of guessing, in the same format as my proposed automated Opentrons workflow: many constructs and conditions processed in a 96-well extraction format, with the TQ providing precise and reproducible data. I could then rank cell lines by omega-3 enrichment, β-carotene yield, and retained growth, choose the best candidate for scale-up, and monitor product quality and consistency during bioreactor runs (via automated sampling). This turns my first big question, “Can the engineered pathways improve nutritional profile without reducing growth or differentiation?”, into a measurable experiment.