<YOUR NAME HERE> — HTBAA Fall 2026

cover image cover image

About me

Contact info

Homework, Labs, and Projects

See the nav bar on the left to look through my work for How To Biomanufacture Almost Anything (Fall 2026)!

Subsections of <YOUR NAME HERE> — HTBAA Fall 2026

Week 1 HW: Final Project Ideas

cover image cover image

Homework #1

  1. What I want to biomanufacture, and why I would like to work in researching and making something along the lines of engineered human cells that get injected next to a painful joint, and release an anti-inflammatory protein and are controlled through magnogenetics. One of the potential proteins I could user is IL-1Ra, sold as anakinra. My target is chronic spine/neck pain from facet joints. I have it pretty severely, and have done loads of treatments through years, which is why I picked it. About 18.7% of U.S. veterans report neck pain and 49.6% report joint pain (NHIS 2018), both well above non-veteran rates. The cervical case is interesting because the options are thin. Steroid injections wear off, the main durable treatment is radiofrequency ablation, burning the nerve that carries the pain signal. It works in someways, but the nerve grows back in six to eighteen months, and you do it again. The current plan is destroying a nerve on a recurring schedule. It’s also where local control matters most. The cervical joints are small and sit within a centimeter or two of the spinal cord, so you can’t solve the problem by flooding the body with drugs and it is too risky to intervene surgically. A magnetic field potentially fits as it passes through tissue, it’s non-invasive, it can be aimed at one joint or area, and a patient could use it on a schedule.
  2. What living system would I use? Human cells, grown in a lab and engineered so the patient’s immune system tolerates them. Inside those there would be a switch out of three parts. A receptor that works like a pull-cord. Most cell receptors are locks: the right chemical key arrives and the lock opens. Here a synNotch/SNIPR-type receptor would stick out of the cell surface folded shut around a hidden cut site. The magnet would then be used for it to unfold, exposing the site. Enzymes in the membrane snip it, the inside end falls off, drifts to the nucleus, and switches on a gene. It doesn’t respond to chemistry. Magnetic beads as the handle. The receptor is built to grab one specific molecule (GFP), so I’d glue GFP onto tiny iron beads. Now the receptor is holding something a magnet can grab. A gene for the anti-inflammatory protein, placed after the switch. Swap that gene and the same machine makes something else. In: culture medium at 37 °C, the GFP-coated magnetic beads, and a magnetic field. What happens: the magnet pulls the beads, the beads pull the receptor open, the gene turns on. Out: the anti-inflammatory protein, at a rate set by the field. Is it physically possible? There is precedent. Gordon et al. pulled on Notch1 with magnetic tweezers and ligand-coated magnetic beads, using a 96-well magnet array [2]. They found the receptor opened at about 1.4 pN in living cells, and my rough estimate is that a magnetic bead in a strong gradient supplies around 12 pN — enough, but not by much. Assumptions:
  3. The magnet really pulls properly. Everything rests on this.
  4. It shuts off in hours, not weeks. Otherwise it isn’t a switch, it’s a delay. It would probably need some degradation tag on the protein.
  5. A wearable magnet reaches the joint. Cervical facet joints sit only 2–4 cm deep.
  6. The cells and beads stay where they were injected for months. If they drift or get cleared, this becomes a therapy you re-dose a few times a year rather than implant once.
  7. How I’d use automation What needs automating isn’t any one lab step it’s the testing. The switch has several settings I don’t know anything about yet. How much of each DNA piece, how many beads, how close the magnet. Im unsure of right combination, I have to test a lot of them. I would use automation through a liquid handling robot as it can run dozens of combinations at once, each mixed the same way, and the software picks the next round based on the last. The step being automated is the liquid handling and screening, the build-and-test loop itself, not any single experiment.
  8. How much, and how long Scale: Veterans treated at VA Boston for a year.

Patients served by VA Boston, FY2025 65,506 [4] × neck pain prevalence [1] 18.7% → 12,250 × severe enough to treat (assumption) 25% → ~3,000 patients Cells per injection 10 million Total: 3 × 10¹⁰ cells a year. That’s about 77 mL of packed cells a third of a coffee cup covers every eligible veteran at VA Boston for a year. How long? From one vial of 10 million cells that’s about 12 doublings around 12 days of growing, plus a week to harvest and freeze and 2–4 weeks of safety testing. Around six weeks for a single batch, and one batch covers the year. At this scale you could even use ordinary primary cells; the immortalized line in Section 2 only becomes necessary if you scale to the whole VA system. 5. What I don’t know yet:

  1. Whether the magnet can pull hard enough. This is the assumption everything else rests on. There’s a well-known critique in this field as Meister showed that one version of magnetogenetics falls short of the energy it would need by five to ten orders of magnitude [5], and other labs couldn’t reproduce the original results [6].
  2. Whether the beads are safe enough to put near a spine. Iron particles sitting on cells aren’t harmless, and the uncomfortable possibility is that the thing delivering the signal is also the thing damaging the cells. Near the cervical spine that matters more than it would in a knee.
  3. I’m coming brand new to the field of biomanufacturing. It is going to take a lot of time and research to pursue what I am initially proposing. AI use: Claude, September 20, 2026. I inquired in building a proposal around magnetic control of engineered mammalian cells, which I first saw in a classmate’s HTGAA 2026 final project (Sami Syed, Magnetically Controlled Neuromorphic Computation) in relation to my personal struggle. I also used it to check whether the science is viable, and to explain how the biological system would function. I also used it to project calculations in testing groups in relation to the VA Boston data. References
  4. Taylor, K. A., Kapos, F. P., Sharpe, J. A., Kosinski, A. S., Rhon, D. I., & Goode, A. P. (2024). Seventeen-year national pain prevalence trends among U.S. military veterans. The Journal of Pain
  5. Gordon, W. R., et al. (2015). Mechanical allostery: evidence for a force requirement in the proteolytic activation of Notch. Developmental Cell
  6. Petzold, C. J., & Mukhopadhyay, A. (2025). From bench to biofactory: high-throughput technologies and automated workflows to accelerate biomanufacturing. Current Opinion in Biotechnology
  7. U.S. Department of Veterans Affairs. VA Boston Healthcare System, About Us (FY2025 patient volume: 65,506)
  8. Meister, M. (2016). Physical limits to magnetogenetics. eLife
  9. Xu, F.-X., et al. (2024). Magnetogenetics as a promising tool for controlling cellular signaling pathways. Journal of Nanobiotechnology, 22, 291

Week 2 HW: DNA Design

Part 0: Set up in Kernel

My work is in the repository HTBAA_2026_Perera, in the folder Perera-Project.

Part 1: Define your expression target

What molecule? Two proteins, from two cassettes on one construct. Cassette A is a chimeric synNotch receptor: signal peptide + anti-GFP nanobody + Notch1 regulatory region and transmembrane domain + Gal4-VP64. Cassette B is human IL-1Ra (anakinra), expressed only when Gal4-VP64 is released from the receptor.

What sequence?

ElementSourceAccession
IL-1RaUniProtP18510, 177 aa incl. native signal peptide
Anti-GFP nanobody LaG17Fridy et al. 2014, Nat Methods 11:1253in synNotch form in Addgene #79127
Notch1 NRR + TMMouse Notch1Q01705 / NM_008714, Ile1427–Arg1752 (Morsut et al. 2016)
Gal4 DNA-binding domainUniProtP04386, aa 1–147
VP64HSV-1 VP164× minimal activation domain

All five are known parts.

The Notch1 region is mouse, not human, although the host is human. Morsut et al. defined the synNotch core in mouse and the validated constructs use it in human cells. The region works mechanically, not by species-specific recognition.

What host? HEK293.

Where does the product go? The receptor goes to the plasma membrane signal peptide in, the transmembrane domain anchoring it with the nanobody outside and Gal4-VP64 inside. IL-1Ra is secreted, using its own native signal peptide.

Part 2: Design your genetic parts

Cassette A — the switch (constitutive)

TypeNameSourceJustification
PromoterEF-1α coreHuman EEF1A1Constitutive and resists silencing over long culture; receptors are consumed when they fire, so supply must be continuous.
KozakGCCACCATGGDesignedConsensus sequence for correct translation initiation.
Peptide CDS (+start −stop)IgK leaderMouse Ig kappaStandard efficient entry to the secretory pathway; carries the cassette’s only start codon.
CDS (−start −stop)LaG17 anti-GFP VHHFridy 2014Binds the GFP-coated bead; LaG17 rather than the tighter LaG16_2 because the bead must release when the field is removed.
CDS (−start −stop)mNotch1 NRR+TMMouse Notch1The force-sensing element: a folded clamp hiding the S2 site, plus the transmembrane S3 site.
CDS (−start +stop)Gal4-VP64GAL4 + VP16Orthogonal to human cells, so the released factor acts only on cassette B; carries the only stop codon.
Poly(A) signalSV40SV40Compact and well validated.

Cassette B — the payload (inducible)

TypeNameSourceJustification
Promoter5× Gal4 UAS + minimal CMVStandard synNotch response elementUAS array is the Gal4-VP64 binding site; minimal CMV is near-silent alone, giving a low off-state.
KozakGCCACCATGGDesignedAs above.
CDS (+start +stop)IL-1RaP18510, 531 bpThe therapeutic payload, kept as one part including its native signal peptide.
Poly(A) signalbGHBovine growth hormoneDiffers from cassette A’s polyA to avoid a repeated sequence in the construct.

Backbone

TypeNameProvides
BackboneLentiviral transfer vector (pHR-type)Origin and AmpR for propagation; LTRs and packaging signal for delivery
CDS (+start +stop)PuroRPuromycin selection of stable transductants

Lentiviral rather than transient, because the experiment applies a field over hours and needs expression stable across the measurement.

Part 4: Optimize and quality-check

Codon optimization. IL-1Ra is a human gene in a human host, so this is about removing rare codons, cryptic splice sites and unwanted restriction sites rather than changing codon tables. Notch1 (GC-rich) and Gal4 (yeast-derived) should change most.

Sequence search. IL-1Ra should match human IL1RN closely. The receptor should return no full-length match, only segment hits to NOTCH1, GAL4, VP16 and camelid VHH frameworks, because it does not exist in nature.

Safety screen. Expect flags on VP16 (herpes virus origin), the lentiviral backbone, and possibly NOTCH1 (oncogenesis). All are explicable: VP64 is an 11-residue activation domain repeated four times, the vector is replication-incompetent, and the Notch fragment has its signalling domain replaced.

Part 5: From design to build

How would you build it? Order both cassettes as synthetic fragments and assemble into the backbone by Gibson assembly. At 3.6 kb split in two this is well within commercial synthesis range, and Gibson joins fragments by designed overlaps rather than restriction sites, so I do not have to purge those sites from the construct.

What does synthesis constrain? Three things are hard to synthesize: VP64 is four tandem repeats, the 5× UAS array is also a repeat, and the Notch1 region is GC-rich. Repeats cause mispriming and recombination. Mitigations: order repetitive regions as separate short fragments, vary codons within the VP64 repeats so the DNA differs while the protein does not, and rely on vendor error correction. Carr et al. (2004) use MutS to remove error-bearing molecules after denaturing and reannealing; because synthesis error is per-base, the rate that matters is the one after correction, which is why 3.6 kb is orderable. Full-plasmid sequencing before use regardless.

Prototype vs scale. Prototyping, DNA is the experiment — one construct plus a variant library of UAS copy numbers, promoter strengths and nanobody affinities, which is what oligo-pool synthesis is for (Kosuri et al. 2010). At manufacturing, DNA is not the product: one GMP plasmid bank is made once, used to generate a vector lot, used to make a master cell bank, and every dose comes from that bank. A one-time cost, not a per-unit one.

Part 6: What don’t you know yet?

1. Whether the off-state is actually off. Minimal CMV behind a UAS array is described as low-background, but these cells would be implanted for months, and constant low-level IL-1Ra with no magnet applied would undermine the premise of a controllable therapy. How to find out: build it with a fluorescent reporter in place of IL-1Ra, make a stable line, and measure baseline over weeks with no field, against a promoterless control and against cells with no receptor. If background is too high, use fewer UAS repeats, a tighter minimal promoter, or add a second layer of repression.

2. Whether the receptor folds and traffics correctly as a four-part fusion. Each segment works in its native context, but fusing them is not guaranteed to preserve folding or membrane topology, and the risk concentrates at the nanobody–Notch junction, where a bad interface could leave the cleavage site permanently exposed or permanently buried. How to find out: surface-stain for the nanobody on intact, non-permeabilized cells to confirm the extracellular domain is outside, and test whether beads bind at all. If they do not, the construct never reaches the force question.

3. Whether expression has to be tuned empirically. I chose EF-1α on the reasoning that receptors are consumed and must be replaced, but I have no estimate of the consumption rate, so I do not know whether I am under- or over-supplying. Too little and the response saturates early; too much and I raise background and metabolic load. How to find out: build a promoter series on the receptor cassette — EF-1α, CMV, PGK and a weak variant — and measure both surface receptor density and induced output per cell.

References

  • Gibson, D. G. et al. Nature Methods 6, 343–345 (2009).
  • Kosuri, S. et al. Nature Biotechnology 28, 1295–1299 (2010).
  • Carr, P. A. et al. Nucleic Acids Research 32, e162 (2004).
  • Morsut, L. et al. Cell 164, 780–791 (2016).
  • Fridy, P. C. et al. Nature Methods 11, 1253–1260 (2014).
  • Gordon, W. R. et al. Developmental Cell 33, 729–736 (2015).
  • Addgene #79127, pHR_pGK_LaG17_synNotch_Gal4VP64 (Lim lab).

AI use

Client: Claude.

Used for: learning the underlying biology, since I came into this course without a biology background; checking part accessions against Addgene, UniProt and finding the primary sources.

Week 3 HW: Cell-Free Reaction Design

Part A: Compare cell-free reaction compositions

A 20 microlitre cell-free reaction: DNA template transcribed by T7 RNA polymerase to mRNA, translated by lysate ribosomes into folded protein, with salts, buffer, amino acids, nucleotides and an energy system supplied at the start A 20 microlitre cell-free reaction: DNA template transcribed by T7 RNA polymerase to mRNA, translated by lysate ribosomes into folded protein, with salts, buffer, amino acids, nucleotides and an energy system supplied at the start

1. Why does the concentration of potassium glutamate and magnesium glutamate differ between compositions? Which is more sensitive?

They do different jobs. Potassium sets ionic strength and is needed in bulk; the base buffer alone supplies 200 mM. Magnesium is a catalytic cofactor at 8–10 mM: it holds the ribosomal subunits associated, screens the charge on mRNA and tRNA, and is required by T7 RNA polymerase and the aminoacyl-tRNA synthetases.

Magnesium is far more sensitive. In Jewett & Swartz Table II, magnesium peaks sharply at 20 mM and loses 25–60% of yield 4–12 mM either side. Potassium stays above 0.9 of maximum anywhere from 150 to 225 mM.

Free magnesium is also not added magnesium. Phosphate-bearing components chelate it, and PEP releases inorganic phosphate as it is consumed, so the magnesium optimum moves with the energy system. The two matched PETase references need 300 nL and 225 nL with nothing about the ribosome changed. Potassium has no comparable coupling.

Glutamate is the counter-ion in both cases because chloride is inhibitory at these concentrations.

2. How does a PEP+NTP formulation differ from a Ribose+NMP formulation?

A cell-free reaction has no metabolism to replenish ATP, so ATP must be regenerated. PEP+NTP supplies finished triphosphates plus phosphoenolpyruvate as a high-energy phosphate donor. Ribose+NMP supplies cheaper monophosphates and relies on the lysate’s surviving central metabolism to phosphorylate them up.

PEP + NTPRibose + NMP
Observed mean314.60274.79
Replicate CV2.8%15.5%
Amino acid mix400 nL1600 nL

About 13% lower yield and five times the replicate variability, using four times the amino acids.

3. Compare two cell-free reaction compositions from the literature

PANOx-SP (Jewett & Swartz 2004) against the cost-optimised direction in Olsen et al. (2026).

PANOx-SP lineageCost-optimised
Design goalMimic the E. coli cytoplasmMinimise cost per gram
EnergyPEPCheap carbon source, native metabolism
NucleotidesFull NTP setMonophosphates
CofactorsFolinic acid, NAD, CoA, spermidine, putrescine, oxalateTrimmed
ReproducibilityCV 2.8%CV 15.5%

Both use glutamate salts rather than chloride and supply all twenty amino acids. The disagreement is which additions earn their cost.

Part B: Design one reaction composition for each protein

sfGFP. No disulfide bonds, reducing conditions. Kept near the reference and adjusted magnesium glutamate and potassium phosphate only. This is the control that shows whether the reaction worked at all.

PETase (TfCut2). One disulfide bond, so the formulation stays close to sfGFP. Added PEG 8000: TfCut2 is an interfacially active cutinase and adsorbs to the polystyrene over a 20-hour incubation. Protein on the wall is invisible to the assay, so the failure reads as poor expression when it is poor recovery.

Reteplase. Nine disulfide bonds, so the oxidising formulation: DTT-free lysate with iodoacetamide, cysteine quench, GSSG/GSH, and DsbC. Adjusted DsbC and HEPES-KOH. DsbC is $5.63 of a $5.70 reaction, 98.8% of reagent cost, so it is the only cost lever that matters on this target.

Community reagent: Brij-35, a non-ionic surfactant. Chosen from the failure mode above — it coats hydrophobic surfaces and keeps partially hydrophobic protein in solution. It was missing from the designer when I proposed it and has since been added at a 10% v/v stock.

Forum. Joined the cfps-coopetition channel.

Week 4 HW: CFPS Batch, Data Analysis, Metascience

A. Design a batch of cell-free reaction compositions

Hypothesis. Glutathione acidifies the oxidising Reteplase reaction (Olsen et al. 2026). If HEPES buffering is limiting at the reference 57.5 mM, raising it should recover yield — and a well-buffered reaction should reach reference titer at half the DsbC.

Itemised reagent receipt for one Reteplase reaction: DsbC $5.632 of a $5.703 total, 98.8% of reagent cost, against HEPES-KOH at $0.00007 Itemised reagent receipt for one Reteplase reaction: DsbC $5.632 of a $5.703 total, 98.8% of reagent cost, against HEPES-KOH at $0.00007

Why. DsbC is $5.632 of a $5.703 Reteplase reaction, 98.8% of reagent cost. HEPES is $0.00007. Lysate, which dominates the other two targets, is 0.4% here. So the only question that matters for cost on this target is how little DsbC will still fold the protein, and buffering is the cheapest thing that might allow less of it.

Crossing the two also removes a confound: a DsbC titration at fixed HEPES has glutathione present throughout and pH drifting over the incubation, so differences along the titration have two possible causes.

The batch. Three HEPES levels × two DsbC levels. All other reagents held at reteplase_standard, water absorbing the difference.

SampleDsbC (nL)HEPES (nL)HEPES (mM)Water (nL)Total
perera_rtp_hepes_dsbc_011,00055057.562520,000
perera_rtp_hepes_dsbc_021,00085072.532520,000
perera_rtp_hepes_dsbc_031,0001,15087.52520,000
perera_rtp_hepes_dsbc_0450055057.51,12520,000
perera_rtp_hepes_dsbc_0550085072.582520,000
perera_rtp_hepes_dsbc_065001,15087.552520,000

Sample 01 reproduces reteplase_standard exactly as the in-batch anchor. The HEPES ceiling is set by the reference recipe’s 625 nL of water. All six validate against CFPSReagentList and Sample from the repository’s models.py; every volume is a multiple of 25 nL.

What each outcome means. Titer rising with HEPES at both DsbC levels means acidification is limiting. Sample 06 matching sample 01 means half the DsbC at higher buffer holds reference titer, a ~50% cut in cost per gram. HEPES helping only at 1,000 nL DsbC means the two interact and DsbC titrations must control pH. No HEPES effect means buffering is already sufficient, which is a useful negative for six wells.

This complements the DsbC titration another student is running rather than duplicating it.

B. Research team discussion, data analysis, metascience

1. Current status of my ideas

Main line is above: pH as a controlled variable in the Reteplase arm.

Second: surfactant rescue for PETase. TfCut2 adsorbs to polystyrene over a 20-hour incubation in a high surface-to-volume well, so the assay would under-report expression that actually happened. Brij-35 was my community reagent proposal and has since been added to the designer.

I did not run an agent to mass-produce compositions. Agent suggestions converge — Brij-35 surfaced repeatedly across different people’s agents — so they are correlated rather than independent, and many correlated compositions take plate space without adding information.

Least sure about: whether pH drift is large enough to matter at 57.5 mM in this lysate over this incubation. That is what the batch is for.

2. Data analysis: 384-well versus 96-well deep-well

The same 80 designs, same lysate lot, run in both formats.

These are not the same reaction. The 384 run was 20 µL read directly; the quad run was 40 µL in 96-well deep-well plates, compressed back to a 384 read plate. Volume is itself a variable.

The 96-well format yields more, with less noise.

Quad 96-well384-well
Median design titer2.71 g/L0.36 g/L
Median replicate CV7.2%14.6%
Designs with CV > 20%4 of 8032 of 80

Median per-design fold is 7.3×.

The ranking does not transfer. Spearman ρ = −0.12 across the 80 shared designs. Top-10 overlap is 0 of 10. The family order inverts: 384 gives PANOx > Ginkgo3 > RFopt, quad gives Ginkgo3 ≈ RFopt > PANOx. The 384 run’s top nine designs are all PANOx; in quad they rank 58–72.

Agreement varies by block — K-phosphate titration holds at ρ = +0.84, while glucose and K-glutamate titrations run to −0.71 and −0.75. Glucose reverses sign, helping in quad and hurting in 384.

Three candidate explanations, untested: evaporative concentration in the deep well, which would lower the apparent magnesium and potassium optima and lift low-Mg recipes into range, matching the observed pattern; better aeration under a larger headspace; and a base buffer lot difference that cannot be separated from format without a same-buffer side-by-side.

This matters because the workflow is 384 → 96 → 2 mL and assumes 384 rankings identify what to carry forward. At ρ = −0.12 that fails, and the effect is reproducible across two runs, so it is systematic rather than noise. The mitigation is to carry a fixed reference panel through both formats so the offset is measured, and to treat 384 as a screen for failure rather than a ranking of success — the K-phosphate block shows which reagent matters does transfer even when how much does not.

3. Metascience: one rubric criterion

Does the result change what we do next, whichever way it comes out? Score each proposal by what each possible outcome would cause the group to do differently. A proposal where every outcome leads to the same next step scores zero.

Novelty rewards the merely untested, and something can be untested because nobody had a reason. Hypothesis strength fails more subtly: the strongest-sounding hypotheses are the most likely to be confirmed, and a confirmed expectation teaches least. Decision-relevance is harder to game, since you must state in advance what each outcome would change.

The 96-well report is the argument for it. Selecting on round-one titer would carry forward exactly the designs that stop winning at the next scale.

Against my own criterion: it favours people who can already articulate consequences, which disadvantages the students this course exists to bring in. It should be paired with a reserved allocation giving every participant at least one composition on the plate.

Final Project

cover image cover image