Week 4: Cloud Lab

  1. WEEK 4 ASSIGNMENT: CFPS REACTION DESIGN FOR SFGFP, PETASE, RETEPLASE

A. DESIGN A BATCH OF CELL-FREE REACTION COMPOSITIONS

{ “experiment_hypothesis”: “Find the glucose level that maximizes sfGFP yield”, “samples”: [ { “sample_id”: “example_glucose_1”, “sample_type”: “experimental”, “reagent_list”: { “base_buffer”: 2000, “lysate”: 5000, “template_sfgfp”: 2000, “magnesium_glutamate”: 250, “nuclease_free_water”: 10750 }, “metadata”: { “protein_target”: “sfGFP”, “comments”: “Low glucose level” } }, { “sample_id”: “example_glucose_2”, “sample_type”: “experimental”, “reagent_list”: { “base_buffer”: 2000, “lysate”: 5000, “template_sfgfp”: 2000, “magnesium_glutamate”: 350, “nuclease_free_water”: 10650 }, “metadata”: { “protein_target”: “sfGFP”, “comments”: “High glucose level” } } ] }

B. RESEARCH TEAM DISCUSSION, DATA ANALYSIS, METASCIENCE

Data Analysis: Familiarize yourself with the autonomous-cfps repository. Experimental results are stored in autonomous_cfps/data/reference_set and data analysis files are in the reference_results folder. Review the sfGFP_control_20260722-39-L_96w_report.pdf. What does it show about how the same 20 µL sfGFP reaction performs in a 384-well plate versus a 96-well deep-well plate? Can you suggest what might explain some of the differences (for example: oxygen access, evaporation).

The same sfGFP formulations performed much better in the quad 96-well deep-well format than in the standard 384-well plate. The median titer increased from 0.36 g/L to 2.71 g/L, a 7.3-fold increase, and the target control increased from 0.35 to 2.65 g/L. The 96-well format also had more consistent results across replicates, with a median CV of 7.2% compared with 14.6% in the 384-well format. Interestingly, the ranking of the formulations changed considerably between formats, suggesting that the plate setup can affect which ingredients and concentrations work best. One possible explanation is evaporation. Water loss during incubation in the deep-well plates could concentrate the reagents and change the effective concentrations of salts such as magnesium and potassium glutamate. Another possibility is better oxygen availability in the deep wells, which could support energy regeneration and improve protein production. However, these explanations have not yet been experimentally confirmed. The report also notes that the two runs used different base buffer lots, so the differences cannot be attributed to plate format alone.

Metascience: With hundreds of proposed reactions and a limited number of experimental wells during round 1 of the coopetition, deciding which experiments to run is itself a scientific question. A shared rubric, a set of criteria we score every proposal against, can make that choice transparent and fair. Propose one rubric criterion you think we should use to decide which experiments make it onto the plate, and explain in a sentence or two why it matters. Examples include novelty relative to what’s already been tested, the strength of the hypothesis, or the expected information gain.

I think we should prioritize experiments that test a new hypothesis or explore a condition that hasn’t already been tested. Since we have a limited number of wells, we should choose experiments that can teach us something useful about the formulation rather than repeatedly testing similar conditions without a clear reason.

  1. Use of AI

Claude Sonnet 5.5.

  1. REFERENCES AND RESOURCES
  • Smith, A. A., et al. (2026). Using a GPT-5-driven autonomous lab to optimize the cost and titer of cell-free https://www.biorxiv.org/content/10.64898/2026.02.05.703998v1

  • Jewett, M. C. (2026). Design-driven optimization of low-cost reagent formulations for reproducible and high-yielding cell-free gene expression. Nature Communications. DOI: 10.1038/s41467-026-69605-8.

  • Olsen, M. L., Copeland, C. E., Sundberg, C. A., Aw, R., Shaver, Z. M., Rao, G., Swartz, J. R., Karim, A. S., &

  • Jewett, M. C., & Swartz, J. R. (2004). Mimicking the Escherichia coli cytoplasmic environment activates long-lived and efficient cell-free protein synthesis. Biotechnology and Bioengineering, 86(1), 19–26. DOI: 10.1002/bit.20026.

  • Silverman, A. D., Karim, A. S., & Jewett, M. C. (2020). Cell-free gene expression: an expanded repertoire of applications. Nature Reviews Genetics, 21, 151–170. DOI: 10.1038/s41576-019-0186-3.

  • Rasor, B. J., Vögeli, B., Landwehr, G. M., Bogart, J. W., Karim, A. S., & Jewett, M. C. (2021). Toward sustainable, cell-free biomanufacturing. Current Opinion in Biotechnology, 69, 136–144. DOI: 10.1016/j.copbio.2020.12.012.