Week 1 HW: Final Project Ideas
HTBAA Homework #1
Due: Tuesday September 22, by 2:30p ET
For your first homework, propose and describe one idea for something you would like to biomanufacture. This could be medicine, material, food, energy, an art, design, or architectural artifact, or beyond. Draw from your own background and interests for inspiration.
The goal of this assignment is not to develop a complete or technically optimized manufacturing process. Instead, we want you to begin connecting four fundamental questions: What do you want to make? → What living system could make it? → How could automation help you make it? → What would it take to make it at a meaningful scale? Include in detail:
(1) What you would like to biomanufacture and why?
Describe the target product or output you would like to make. Why are you interested in making it? Your motivation might be utilitarian—for example, addressing a problem in health, sustainability, food, energy, or manufacturing—but it does not need to be. Your project might instead have a social, cultural, artistic, or personal motivation. Clearly articulate what you want to make, who or what it is for, and why you think it is interesting or important.
Target: Paper-based or hydrogel-based trace gas sensors specifically tuned to detect hydrogen (H2), carbon dioxide (CO2), and hydrogen sulfide (H2S) in human breath.
Motivation: These gasses are used to diagnose issues with the gut microbiome. Trace levels of these specific gases in human breath can be expencive and challenging to measure. Currently, accurately measuring these gases at parts-per-million (ppm) or parts-per-billion (ppb) concentrations requires either bulky gas chromatography equipment. Theere is some sucess in usingsolid-state MEMS sensors.
For Hydrogen (H2) Palladium MEMS or Metal Oxide Semiconductor (MOx)
- MOx sensors are highly sensitive to humidity
- MOx sensors are will cross-react with other reducing gases
For Carbon Dioxide (CO2) NDIR (Non-Dispersive Infrared) or Thermal Conductivity MEMS
- NDIR sensors are almost immune to cross-sensitivity from other gases, but they are extreamly sensitive to condensation
- diagnosing some digestive issues (H. pylori) requires measuring the exact ratio of the Carbon-13 isotope to the Carbon-12 isotope (13CO2 / 12CO2). Standard NDIR/MEMS sensors cannot differentiate between isotopes.
- Thermal conductivity sensors are impacted by ambient temperature or the presence of other gases.
For Hydrogen Sulfide (H2S) Doped MOx MEMS or Micro-Amperometric (Electrochemical)
- H2S sensors easily cross-react with other volatile sulfur compounds (like methyl mercaptan) and broad Volatile Organic Compounds (VOCs) found in breath (from food, mouthwash, or endogenous metabolism).
- Condensation from breath will immediately blind or destroy an electrochemical sensor’s membrane and heavily disrupt a MOx sensor’s electrical baseline
- High concentrations of H2S can permanently bind to and “poison” metal oxide sensors, drastically shortening their lifespan. They are also easily poisoned by siloxanes (found in cosmetics and shampoos)
Biomanufacturing these sensors using engineered proteins may offer a distinct advantage: biological receptors operate natively at ambient temperatures and might achieve chemical specificity without cross-reacting with the hundreds of other volatile organic compounds (VOCs) present in human breath. The goal is to create a low-cost, disposable diagnostic strip that changes color or fluoresces when exposed to specific breath gases. This also avoids the risk of damagin and expensive sensor. With test strips if they are damaged they can be mroe easily replaced and or consumable anyways.
(2) What living system would you use?
Propose at least one living-system manufacturing chassis that could produce your target—for example, a microbial, mammalian, or cell-free system. At a high level, describe how the system would make your target product. What goes into the system? What biological process or processes occur? What comes out? You do not need to design the complete biological system yet. Make reasonable assumptions where necessary and identify them.
Regection reasons for livign cells:
- Living cells are possibly a regulatory and safety nightmare.
- Shelf life is poor and long term storage condiditions are not practical
- Form factor is impractical for end user
- Transportation is impractical
- live cells might die or not be sensitive fast anough to these gasses to be practical.
Escherichia coli (E. coli) Crude Lysate A common choice for prototyping cell-free diagnostics.
Pros:
- Highest Yield: Capable of producing the highest amount of protein (often milligrams per milliliter of reaction).
- Lowest Cost: E. coli grows rapidly in cheap media, making industrial scale-up incredibly cost-effective.
- Proven Lyophilization: Highly optimized protocols exist for freeze-drying E. coli extracts onto paper while retaining activity for months.
- Rapid Prototyping: Transcription and translation are coupled, allowing you to go from a raw DNA plasmid to functional sensor proteins in 2 to 4 hours.
Cons:
- Endotoxin Hazard: As a Gram-negative bacterium, it is packed with toxic lipopolysaccharides (LPS) which can trigger severe immune responses if inhaled or exposed to human mucous membranes.
- The “Black Box”: Crude extract contains endogenous proteases and nucleases that can chew up your synthetic DNA or degrade your sensor proteins over time.
- No Post-Translational Modifications: It lacks the biological machinery (chaperones) to properly fold complex mammalian proteins or add sugar chains (glycosylation).
Mitigation methods:
- Use an “Endotoxin-Free” Mutant Strain: I propose using a genetically modified strain specifically designed for medical biomanufacturing, such as ClearColi™.
- Physical Encapsulation (Hardware Safety): the paper strip must be separated from the mouthpiece by a hydrophobic, gas-permeable membrane (like a thin sheet of PTFE/Teflon or Nafion).
- Switch to a Eukaryotic Cell-Free System
Eukaryotic Lysates (Wheat Germ, Rabbit Reticulocyte, Yeast)
- Pros:
- Completely Endotoxin-Free: Eukaryotic cells do not produce LPS, immediately solving the primary biological safety hazard for a human breath analyzer.
- Complex Protein Folding: They contain the proper chaperones to fold complex, multi-domain proteins and can perform post-translational modifications.
- Cons:
- Lower Yields: They typically produce significantly less protein per milliliter than E. coli.
- High Cost & Complex Scaling: Harvesting reticulocytes from rabbits or processing toasted wheat germ is vastly more expensive and difficult to scale than fermenting a vat of bacteria.
- Slower Kinetics: Eukaryotic translation is often slower, which might delay the time-to-result for a rapid diagnostic.
Alternative Bacterial Chassis (Bacillus subtilis or Vibrio natriegens)
- Pro:
- Con:
The PURE System (Protein synthesis Using Recombinant Elements)
- Pro:
- Purity & Control:
- High Stability:
- Great for Engineering:
- Con:
- Exorbitant Cost:
(3) How would you use automation?
Identify at least one automation technology that you would combine with your living system. This could include a large-scale Cloud Lab, a desktop liquid-handling robot such as an Opentrons, a programmable microfluidics platform such as Nuclera’s, or another automation technology. Describe what part of the biomanufacturing workflow you would automate and why. For example, you might automate liquid handling, culturing, assembly, screening, sampling, measurement, optimization, or another step.
Technology: An automated desktop liquid handler, such as the Opentrons OT-2, paired with an automated plate reader.
Workflow Integration: Automation is critical for the prototyping and optimization phase. Formulating a cell-free sensor requires balancing dozens of variables: lysate concentration, DNA template ratios, buffer pH, and the matrix material (hydrogel vs. paper). The Opentrons would be programmed to rapidly dispense varying micro-aliquots of these components into 384-well microplates. We would then expose these plates to calibrated gas mixtures using a manifold and read the resulting fluorescence. The automation allows us to map the entire parameter space to find the formulation with the fastest reaction kinetics and highest signal-to-noise ratio quicker.
(4) How much would you need to make, and how long would it take?
Perform a back-of-the-envelope calculation estimating what it would take to manufacture your target at a meaningful scale.
(a) How much? Define a scale relevant to your project and calculate approximately how much of your target product you would need to manufacture. For example, if you are producing a medicine, you might estimate the amount required to treat 1,000 people, everyone in Massachusetts, or everyone in the world. If you are producing a building material, you might calculate the amount required for one structure or an entire neighborhood. If you are producing an art or design artifact, define an appropriate scale yourself. Clearly show your calculation, including units, assumptions, and sources for important numbers.
(b) How long? Using your proposed living system and automation technology, estimate how long it would take to manufacture that amount. Consider quantities such as production rate, yield, volume, number of parallel experiments or reactors, automation throughput, or whatever parameters are most appropriate for your system. You may discover that the automation technology you would use to prototype your system is very different from what you would use to manufacture at scale. If so, describe both. Again, we are looking for a reasonable engineering estimate. Show your assumptions and calculations.
Totally an AI Wild guess:
(a) Scale: Let’s define our scale as a pilot clinical trial requiring 10,000 sensor strips.
- Assume each paper test strip requires a 5 µL spot of the active cell-free sensor reaction.
- 10,000 strips * 5 µL/strip = 50,000 µL = 50 mL of total active cell-free reaction volume.
(b) Time: To manufacture this pilot batch, the process breaks down as follows:
- Biomass Production (2 days): Growing a standard 5L benchtop bioreactor of the source E. coli strain to a high optical density.
- Lysate Preparation (1 day): Harvesting, washing, lysing the cells, and centrifuging to extract the raw active lysate. A 5L culture easily yields hundreds of milliliters of lysate.
- Sensor Synthesis (6 hours): Combining the lysate with the DNA templates and energy buffers, and running the bulk cell-free reaction to synthesize the sensor proteins.
- Automated Dispensing (3 hours): Using an industrial micro-dispenser to spot the 50 mL solution across 10,000 paper strips (at ~1 strip per second).
Total manufacturing time: Approximately 3.5 to 4 days to produce the biological active material for 10,000 pilot tests.
5. What don’t you know yet?
After completing your analysis, identify the 2–3 biggest technical unknowns, bottlenecks, or assumptions in your proposed biomanufacturing system. What would you need to learn, measure, or experimentally determine to know whether your idea could actually work?
The 3 biggest technical bottlenecks to test:
- Reaction Kinetics vs. Exposure Time: A single human exhalation lasts only a few seconds. We do not know if the biological gas-binding event occurs rapidly enough to trigger a visible signal in that short window, or if the breath needs to be captured in a bag and exposed to the sensor over several minutes.
- Humidity and Cross-Reactivity: Human breath is nearly 100% relative humidity. We must experimentally determine if heavy water vapor condenses and washes out the lyophilized proteins on the paper matrix, or if the sensor cross-reacts with other VOCs.
- Shelf-Life Stability: While cell-free systems can be freeze-dried, their stability at fluctuating room temperatures degrades over time. We need accelerated aging tests to see if the sensors remain viable after 6+ months in storage.
Feel free to use AI and our learning tools to be shared in recitation to assist you, but remember that you will present in class, so make sure you have a solid understanding of your responses.
Please also cite your AI client and prompts.
Readings:
- Asin-Garcia, E., Fawcett, J. D., Batianis, C., & Martins dos Santos, V. A. P. (2025). A snapshot of biomanufacturing and the need for enabling research infrastructure. Trends in Biotechnology, 43(5), 1000–1014. https://doi.org/10.1016/j.tibtech.2024.10.014
- Averesch, N. J. H., Berliner, A. J., Nangle, S. N., Zezulka, S., Vengerova, G. L., Ho, D., Casale, C. A., Lehner, B. A. E., Snyder, J. E., Clark, K. B., Dartnell, L. R., Criddle, C. S., & Arkin, A. P. (2023). Microbial biomanufacturing for space-exploration—what to take and when to make. Nature Communications, 14, 2311. https://doi.org/10.1038/s41467-023-37910-1
- Karim, A. S. & Jewett, M. C. (2021). “Toward sustainable, cell-free biomanufacturing.” Current Opinion in Biotechnology 69, 136–144. DOI: 10.1016/j.copbio.2020.12.012.
- Petzold, C. J., & Mukhopadhyay, A. (2025). From bench to biofactory: High-throughput technologies and automated workflows to accelerate biomanufacturing. Current Opinion in Biotechnology, 94, 103320. https://doi.org/10.1016/j.copbio.2025.103320
- Yap, W. S., Choudhury, D., & Suntornnond, R. (2023). Towards biomanufacturing of cultured meat. Trends in Biotechnology, 41(3), 292–294. https://doi.org/10.1016/j.tibtech.2023.01.014
- Ye, J.-W., Lin, Y.-N., Yi, X.-Q., Yu, Z.-X., Liu, X., & Chen, G.-Q. (2023). Synthetic biology of extremophiles: A new wave of biomanufacturing. Trends in Biotechnology, 41(3), 342–357. https://doi.org/10.1016/j.tibtech.2022.11.010
- Zhang, Y.-H. P., Sun, J., & Ma, Y. (2017). Biomanufacturing: History and perspective. Journal of Industrial Microbiology & Biotechnology, 44, 773–784. https://doi.org/10.1007/s10295-016-1863-2
Readings Folder: https://drive.google.com/drive/folders/1wX9w_MaJ3TFwHMyPp51b2vJ4mxkUNibf?usp=sharing
Sources:
AI Citation:
- Client: Gemini
- Prompts Used:
- “I have a project assignment not for marks on a free course. I want to explore the possability to make sensors for measuring samples of trace gasses. Possibly for doign trace gas analysis of human breath for hydrogen, CO2 and H2S as those are somewhat difficult to measure accuratly wiht sensors at low cots… [Included the full HTBAA Homework #1 prompt]”
- “how viable is this idea, has it been done”
- “I can imagine breathing into a bag or balloon of a fixed volume to take the sample from… Alternatively some type of flow rate limiter might work with a sensor to measure the total flowed volume over the sample paper.”
- “What type of low-power miniature valves could be controlled by a microcontroller to trap the breath sample over the sensor?”
- “what mems sensorts are used for each of these gasses and what are their limitations such as cross sensitivity and moisture sensitivity and risk of contamination. Also are they sensitive enought to actualy diagnose issues in human digestions”
- “why: What living system would you use? Chassis: A Cell-Free Protein Synthesis (CFPS) system derived from E. coli lysate.”
- “but there are safety issues with E. coli Lysate”
- “list a bullet form of pros and cons to E. coli Lysate and then also list for other options”
- “provide me a list of sources for this last answer… and for the MEMS sensor data… in scientific style [and in a markdown text box]”
Cell-Free Protein Synthesis (CFPS) & Biomanufacturing Sources
- Carlson, E. D., Gan, R., Hodgman, C. E., & Jewett, M. C. (2012). Cell-free protein synthesis: Applications come of age. Biotechnology Advances, 30(5), 1185–1194. https://doi.org/10.1016/j.biotechadv.2011.09.016
- Jung, J. K., Alam, K. K., Verosloff, M. S., Capdevila, D. A., Desmau, M., Clauer, P. R., Lee, J. W., Nguyen, P. Q., Pastén, P. A., Matias, S. J., Bingol, K., Giedroc, D. P., Collins, J. J., & Lucks, J. B. (2020). Cell-free biosensors for rapid detection of water quality. Science Advances, 6(50), eaaz2869. https://doi.org/10.1126/sciadv.aaz2869
- Kelwick, R., Webb, A. J., MacDonald, J. T., & Freemont, P. S. (2016). Development of a Bacillus subtilis cell-free transcription-translation system for prototyping regulatory elements. Metabolic Engineering, 38, 370–381. https://doi.org/10.1016/j.ymben.2016.09.008
- Pardee, K., Green, A. A., Ferrante, T., Cameron, D. E., DaleyKeyser, A., Yin, P., & Collins, J. J. (2014). Paper-based synthetic gene networks. Cell, 159(4), 940–954. https://doi.org/10.1016/j.cell.2014.10.004
- Wang, Y., Zhang, W., Wu, X., & Li, Z. (2022). Cell-free PURE system: Evolution and achievements. Frontiers in Bioengineering and Biotechnology, 10, 878345. https://doi.org/10.3389/fbioe.2022.878345
- Wiegand, D. J., Lee, H. H., Ostrov, N., & Church, G. M. (2018). Cell-free protein synthesis from fast-growing Vibrio natriegens. Frontiers in Microbiology, 9, 2942. https://doi.org/10.3389/fmicb.2018.02942
MEMS Gas Sensors & Breathomics Sources
- Gatty, H. K., Stemme, G., & Roxhed, N. (2018). A miniaturized amperometric hydrogen sulfide sensor applicable for bad breath monitoring. Micromachines, 9(12), 612. https://doi.org/10.3390/mi9120612
- Li, Y., Chen, Z., et al. (2025). A ZnO packaged MEMS hydrogen sensor for reliable SIBO breath analysis with anti-H2S interference. Chemical Engineering Journal, 522, 167331. https://doi.org/10.1016/j.cej.2025.167331
- Shin, H., Kim, D. H., Jung, W., Jang, J. S., Kim, Y. H., Lee, Y., Chang, K., Lee, J., Park, J., Namkoong, K., & Kim, I. D. (2021). Surface activity-tuned metal oxide chemiresistor: Toward direct and quantitative halitosis diagnosis. ACS Nano, 15(9), 14207–14217. https://doi.org/10.1021/acsnano.1c01350
- Sun, Y., Han, L., et al. (2018). Simultaneous detection of hydrogen and methane in breath for the diagnosis of small intestinal bacterial overgrowth by fast gas chromatography. Analytical Methods, 10(35), 4329-4336. https://doi.org/10.1039/C8AY01128C
- Tai, H., Wang, S., Duan, Z., & Jiang, Y. (2020). Metal oxide-based gas sensors for the detection of exhaled breath markers. Sensors, 20(11), 3096. https://doi.org/10.3390/s20113096
- Zhang, Y., Wang, X., et al. (2024). Development of a compact NDIR CO2 gas sensor for a portable device. Micromachines, 15(10), 1203. https://doi.org/10.3390/mi15101203