Week 4 LAB: Cell-Free Manufacturing

Week 4: Designing Cell-Free Reactions

HTBAA 2026, Homework 4. October 20, 2026.

Starting point

Most of my time this week went into one line of the Week 3 handout. It’s the correction from Ronan, highlighted in yellow:

The DSB lysate for Reteplase is the same strain as the regular sfGFP/PETase E. coli. Glutathione reductase and thioredoxin reductase are intact. The DSB lysate just goes through Iodoacetamide treatment + Cysteine quench.

The summary table on the next page still says BL21 Star (DE3) Δgor, so the two parts of the handout disagree. I’m going with the correction, but it’s worth flagging for anyone who designs straight off the table.

The reason it matters: Reteplase needs nine disulfide bonds, all paired correctly, or it has no activity. You get those bonds by making the reaction oxidizing with a GSSG/GSH buffer. If the lysate were Δgor, that oxidizing state would just hold steady for the whole reaction. But with glutathione reductase still active, it won’t. The enzyme keeps converting GSSG back to GSH the entire time you’re incubating.

So whatever ratio I set at the start isn’t the condition the protein folds in. It’s the starting point of something that’s decaying. The question I ended up designing around isn’t how oxidizing the reaction should be, it’s how long the oxidizing window stays open and whether that’s long enough.

Part A: my batch

Four Reteplase reactions, identical except for GSSG. I held GSH constant and adjusted water so each one lands at exactly 20,000 nL.

Hypothesis: residual reductase activity consumes GSSG during the reaction, so the oxidizing conditions fade. Starting above the nominal 1:1 should keep conditions oxidizing long enough for the nine disulfides to pair correctly and give more active Reteplase, up to some point where over-oxidation starts damaging the translation machinery and yield falls off.

SampleGSSGGSHRatioWater
ret_redox_1200 nL200 nL1:12,550 nL
ret_redox_2400 nL200 nL2:12,350 nL
ret_redox_3800 nL200 nL4:11,950 nL
ret_redox_41,600 nL200 nL8:11,150 nL

Every volume is a multiple of 25 nL, each reaction totals exactly 20,000 nL, and the fixed components (5,000 nL lysate, 2,000 nL template, 2,000 nL base buffer) aren’t modified.

Readout is the initial rate of IPR-AMC cleavage. If the signal climbs across all four, the decay idea holds and 1:1 is under-oxidizing, so I’d push the range higher next round. If it’s flat, GSSG isn’t what’s limiting and I’d go sweep DsbC instead. If it rises and then falls, that locates the ceiling, which is the most useful outcome of the three.

One problem with this design that I want to be upfront about: since GSH is fixed, total glutathione goes up along with the ratio. If I see an effect I can’t immediately tell whether it came from the ratio or just from having more glutathione around. The clean follow-up holds total glutathione constant and varies only the ratio. I’d rather flag that myself than have it come up in recitation.

Batch JSON
{
  "experiment_hypothesis": "The DSB lysate is not glutathione-reductase deficient (per Ronan's correction to the Week 3 handout: the Reteplase DSB lysate is the same BL21 Star (DE3) strain as the sfGFP/PETase lysate, with glutathione reductase and thioredoxin reductase intact, and is only IAM-treated + cysteine-quenched). Residual reductase activity should therefore consume GSSG over the course of the reaction, so the oxidizing potential set at t=0 decays. Raising the initial GSSG:GSH ratio above the nominal 1:1 should sustain an oxidizing environment long enough for correct pairing of Reteplase's nine disulfides and increase active Reteplase titer, with a maximum beyond which off-target oxidation of lysate enzymes reduces yield.",
  "samples": [
    {
      "sample_id": "ret_redox_1",
      "sample_type": "experimental",
      "reagent_list": {
        "base_buffer": 2000,
        "lysate": 5000,
        "template_reteplase": 2000,
        "potassium_glutamate": 2000,
        "magnesium_glutamate": 300,
        "amino_acids": 2000,
        "atp": 500,
        "gtp": 350,
        "ctp": 350,
        "utp": 350,
        "phosphoenolpyruvate": 1500,
        "folinic_acid": 150,
        "spermidine": 100,
        "nad": 100,
        "coenzyme_a": 100,
        "dsbc": 250,
        "gssg": 200,
        "gsh": 200,
        "nuclease_free_water": 2550
      },
      "metadata": {
        "protein_target": "Reteplase",
        "comments": "Nominal 1:1 GSSG:GSH. Baseline if the lysate did NOT consume GSSG."
      }
    },
    {
      "sample_id": "ret_redox_2",
      "sample_type": "experimental",
      "reagent_list": {
        "base_buffer": 2000,
        "lysate": 5000,
        "template_reteplase": 2000,
        "potassium_glutamate": 2000,
        "magnesium_glutamate": 300,
        "amino_acids": 2000,
        "atp": 500,
        "gtp": 350,
        "ctp": 350,
        "utp": 350,
        "phosphoenolpyruvate": 1500,
        "folinic_acid": 150,
        "spermidine": 100,
        "nad": 100,
        "coenzyme_a": 100,
        "dsbc": 250,
        "gssg": 400,
        "gsh": 200,
        "nuclease_free_water": 2350
      },
      "metadata": {
        "protein_target": "Reteplase",
        "comments": "2:1. First compensation step for glutathione reductase activity."
      }
    },
    {
      "sample_id": "ret_redox_3",
      "sample_type": "experimental",
      "reagent_list": {
        "base_buffer": 2000,
        "lysate": 5000,
        "template_reteplase": 2000,
        "potassium_glutamate": 2000,
        "magnesium_glutamate": 300,
        "amino_acids": 2000,
        "atp": 500,
        "gtp": 350,
        "ctp": 350,
        "utp": 350,
        "phosphoenolpyruvate": 1500,
        "folinic_acid": 150,
        "spermidine": 100,
        "nad": 100,
        "coenzyme_a": 100,
        "dsbc": 250,
        "gssg": 800,
        "gsh": 200,
        "nuclease_free_water": 1950
      },
      "metadata": {
        "protein_target": "Reteplase",
        "comments": "4:1. Mid compensation."
      }
    },
    {
      "sample_id": "ret_redox_4",
      "sample_type": "experimental",
      "reagent_list": {
        "base_buffer": 2000,
        "lysate": 5000,
        "template_reteplase": 2000,
        "potassium_glutamate": 2000,
        "magnesium_glutamate": 300,
        "amino_acids": 2000,
        "atp": 500,
        "gtp": 350,
        "ctp": 350,
        "utp": 350,
        "phosphoenolpyruvate": 1500,
        "folinic_acid": 150,
        "spermidine": 100,
        "nad": 100,
        "coenzyme_a": 100,
        "dsbc": 250,
        "gssg": 1600,
        "gsh": 200,
        "nuclease_free_water": 1150
      },
      "metadata": {
        "protein_target": "Reteplase",
        "comments": "8:1. High compensation; tests the upper edge before off-target oxidation of lysate enzymes costs titer."
      }
    }
  ]
}

The batch I’d queue next is an sfGFP drop-out screen. Lysate dominates cost at about $4.00/mL and a quarter of every reaction, but its volume is fixed by the rules, so the biggest line item isn’t something we can touch. That leaves raising yield, or cutting the expensive optional reagents: coenzyme A at roughly $104/mL, NAD around $33/mL, and CTP/GTP/UTP at $28 to $39/mL. Run a baseline plus one reaction with each of those removed. If yield holds without a reagent, that’s straightforward savings. If yield drops, you’ve learned where the energy and cofactor system is actually doing work. There’s no uninformative outcome, which is more than I can say for most single compositions.

Part B

Where my thinking is

For Reteplase, the lever is time rather than setpoint, for the reason above.

On cost, since lysate volume is locked, a 20% improvement in titer is worth more than almost any reagent substitution. Cutting expensive reagents only pays where it doesn’t cost yield, which is what the drop-out screen is for.

I don’t think one composition will win across all three proteins. They span zero, one, and nine disulfide bonds, and magnesium optimum alone tends to move between templates. I’d rather submit three protein-specific batches. If something does happen to work across all three, that’s an interesting result, but I don’t want it to be the design target.

Something I’d like to ask the Adamala, Borkowski, and Styczynski labs: DsbC needs a particular redox state at its own active site to function. In a lysate that’s been IAM-treated but still has working reductases, does DsbC stay functional long enough to matter? If it doesn’t, then paying for more of it is wasted and the Reteplase approach needs rethinking.

384-well vs 96-well deep

I wasn’t able to open sfGFP_control_20260722-39-L_96w_report.pdf from the repo, so I still need to fill in the actual mean and CV values from reference_results. The reasoning below doesn’t depend on them.

It’s the same 20 µL either way, but the shape is completely different. In a 384-well plate that volume is shallow and wide with a lot of air contact. In a 96-well deep plate it’s a small puddle at the bottom of a tall narrow column. Four things follow, and they don’t all push the same direction.

Oxygen access is my main suspect for sfGFP specifically. The handout notes the chromophore needs an oxygen-dependent oxidation step to finish forming, which means fluorescence reports both how much protein got made and how much of it has matured. The shallow well breathes easily; the puddle at the bottom of a deep well doesn’t. If the deep-well reading is lower, incomplete maturation is a good candidate, and there’s a way to check: the deep-well signal should still be rising after the 384-well signal has leveled off. If the report includes a time course, that distinguishes less protein from the same protein that hasn’t lit up yet.

Evaporation works the other way. The 384 well loses water faster, concentrating everything in it including magnesium, which has a sharp optimum. A reaction can drift off its optimum partway through, and outer wells drift more than inner ones. So evaporation predicts noisier and more position-dependent results in 384, not necessarily lower ones.

The reader is a confound I’d want ruled out before claiming anything biological. Fluorescence per molecule isn’t comparable across plate types once well width, meniscus shape, and distance from the optics change, and a small volume at the bottom of a deep well is an awkward target for a top-reading instrument. Each format needs its own standard curve for the comparison to mean anything.

Dispensing and mixing is the last one. Firing nanoliter droplets into the bottom of a deep well is harder than into a shallow one, and a small puddle doesn’t mix well on its own. That predicts more well-to-well scatter in the deep-well format independent of the average.

For the coopetition the practical consequence is that 384-well rankings don’t automatically survive the move to 96-well confirmation, and the compositions most at risk are the ones whose advantage depends on oxygen, which plausibly includes the oxidizing Reteplase formulations.

Rubric criterion

I’d score a proposal on how much it tells us that the rest of the plate doesn’t already tell us, rather than on how good it looks by itself.

The failure mode for a crowdsourced plate isn’t bad proposals. It’s a few hundred reasonable proposals all testing the same popular hunch at slightly different concentrations, so 320 wells end up buying one number. Scoring each proposal against the set that’s already been selected makes that redundancy visible while there’s still time to fix it. It also favors clean one-variable sweeps over isolated compositions, since a single winner tells you that it won but not why, and why is the part round 2 can actually build on.

Part C

Didn’t attempt the agentic contribution this round. The batch was assembled by hand and checked with a script rather than submitted through an agent token.

Open items

The reagent key names are educated guesses based on the example in the handout and extended by analogy, so they need checking against the approved list before the validator rejects them. Volumes aren’t concentrations, so whether 200 nL of GSSG is a reasonable 1:1 anchor depends on the stock concentrations in the designer, and if the anchor is off the whole sweep shifts with it. I still need the numbers from the repo report for the plate comparison. And I want to raise the Δgor table discrepancy in the cfps-coopetition channel.