Week 9 HW: Neuromorphic Genetic Circuits
Question 1: Uveal Melanoma Classifier
Biological and Computational Rationale: The objective of this circuit is to act as a single-layer artificial neural network (a Perceptron) capable of distinguishing Uveal Melanoma cells from healthy cells based on two specific biomarkers: TNFSF10 (X1) and TRPM1 (X2). To achieve this, the genetic circuit utilizes post-transcriptional regulation via Endoribonucleases (ERNs). X1 drives the expression of the Csy4 ERN, while X2 drives the expression of the CasE ERN. The Csy4 enzyme is designed to recognize and cleave a specific target sequence (Csy4_rec) placed upstream of the CasE mRNA. This creates an inhibitory genetic cascade: high levels of X1 (TNFSF10) will suppress the translation of CasE.
Therapeutic Output:
In a clinical setting, the output of this logic gate should be a therapeutic molecule. I selected Caspase-9 as the molecular output. Caspase-9 is an initiator caspase that triggers the intrinsic apoptotic pathway. Therefore, when the circuit correctly identifies the melanoma marker profile, it will synthesize Caspase-9, leading to programmed cell death (apoptosis) exclusively in the cancer cells.
For the Biocompiler simulation, the Wizard does not have Caspase-9 in its library, so mNeonGreen (a fluorescent protein) was used as a visual proxy to represent the activation of the apoptosis pathway.
Initial Simulation (Baseline):
Below is the initial configuration in the BUILD tab and the resulting heatmap in the PREDICT tab. The dark blue region represents high output expression (activation of Caspase-9), while the white region indicates low expression (healthy cells).


Modified Simulation (Tuning the Network Weights):
To demonstrate the tunability of the genetic circuit, I modified the concentrations (gene dosage) of the ERNs and the output in the BUILD tab.


Observation: Why did the heatmap gradient remain visually identical despite changing the concentrations? At first glance, one might expect the graph to change shape when concentrations are altered. However, the mathematical topology of this circuit remains identical. In machine learning, this circuit functions as a linear Perceptron. The visual gradient in the heatmap represents the decision boundary, governed by the equation (w1X1 + w2X2 + Bias = 0). By changing the concentrations of Csy4 and CasE, I am effectively altering the weights and the bias of the neural network. This shifts the threshold (moving the line slightly up or down), but it does not change the angle (slope) of the boundary. Because the genetic wiring (the ERN topology) was not changed, the fundamental mathematical relationship between X1 and X2 remains linear. To fundamentally alter the shape of the classification boundary (e.g., to make it a curved, non-linear decision boundary), the biological topology must be changed (e.g., adding a second layer of ERNs).
Question 2: Triple-Negative Breast Cancer (TNBC) Classifier
Disease Background & Biomarker Selection: I selected Triple-Negative Breast Cancer (TNBC), which is characterized by the lack of estrogen, progesterone, and HER2 receptors, making it highly aggressive and difficult to treat. The biological markers chosen for this circuit are EGFR (Epidermal Growth Factor Receptor, X1) and KRT5 (Keratin 5, X2). Transcriptomic profiling (RNA-seq data) demonstrates that basal-like TNBC tumors exhibit significantly elevated expression of both EGFR and KRT5 compared to normal breast epithelium.
Input/Output Scatterplot Logic: Based on representative clinical expression data (FPKM), I generated a scatterplot in Excel to visualize the classification space. As shown in the figure, normal ‘Healthy’ breast tissue (grey dots) clusters strictly in the low/low quadrant (bottom left), indicating low baseline expression. In contrast, the ‘Diseased’ TNBC samples (yellow dots) cluster in the high/high quadrant (top right), reflecting the known overexpression of both biomarkers in basal-like tumors. The circuit’s goal is to draw a linear decision boundary that separates these two distinct populations, ensuring the therapeutic output only activates in the high/high disease state.

Circuit Design & Prediction:
- Genetic Logic: To demonstrate the modularity of neuromorphic programming, I completely redesigned the ERN cascade for this specific cancer. X1 (EGFR) drives the expression of the PgU ERN, which represses the CasE ERN produced by X2 (KRT5).
- Therapeutic Output: The molecular output is Caspase-3, an executioner caspase that guarantees cell death once activated.
- Simulation Result: As seen in the heatmap, the circuit successfully acts as an AND gate. It only triggers a high output (dark blue) when both EGFR and KRT5 are highly expressed, ensuring healthy cells (low expression) remain unaffected (white).

Question 3: Non-Medical Application - Heavy Metal Water Biosensor
Environmental Rationale: Moving beyond medicine, neuromorphic circuits can be used for environmental biosafety. I designed a whole-cell biosensor to detect water contaminated with heavy metals: Mercury (X1) and Arsenic (X2). In developing nations, industrial runoff often contaminates water supplies, and rapid field-deployable sensors are desperately needed.
Circuit Design & Prediction:
- Genetic Logic: I inverted the ERN cascade to create a strict biosafety gate. X1 (Mercury) drives the expression of CasE, which represses the Csy4 ERN (driven by X2, Arsenic).
- Biological Output: The output is a fluorescent reporter protein (mNeonGreen).
- Simulation Result: The heatmap demonstrates that the circuit functions as an AND gate. It remains completely off (white area) in clean water with trace metals, and only turns on (dark blue area) when BOTH contaminants exceed toxicological safety thresholds. This design prevents false alarms from naturally occurring background levels of a single metal, providing a visual, low-cost warning system for severe environmental toxicity.