<?xml version="1.0" encoding="utf-8" standalone="yes"?><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Week 7 HW: 📏 Measurement &amp; Assays :: shaymaa-yakout</title><link>https://pages.htgaa.org/2026b/shaymaa-yakout/week-07-hw-mass-spec/index.html</link><description>Week 7 HW: 📏 Measurement &amp; Assays 1️⃣ Question 1: SDS-PAGE 🧫 I chose SDS-PAGE, a technique I learned about in one of my university courses to check the GFP made by transformed bacteria.&#10;a) 💉 Sample introduction: I lyse the cells, mix the protein with sample buffer (SDS + DTT/β-mercaptoethanol + glycerol + dye), heat it to ~95 °C, and pipette it into the wells of a polyacrylamide gel. One well gets a protein ladder. b) 🔬 Property used: Size. SDS unfolds proteins and gives them a charge proportional to their length, so only molecular weight matters. In an electric field, small proteins move through the gel mesh faster than big ones. c) 📊 What I can measure: approximate molecular weight, whether my protein is expressed (a band at ~27 kDa), purity (extra bands), rough relative amount (band intensity), and disulfide-linked chains (reducing vs non-reducing). d) 🔦 Detection: I stain the gel (Coomassie, or silver for more sensitivity), image it, and plot log(MW) vs distance migrated for the ladder to read off my band’s size. Band intensity is quantified with ImageJ. e) ⚠️ Limitations: low resolution, only semi-quantitative, no proof of protein identity, denaturing (function is lost), low throughput, and much less sensitive than mass spec. 2️⃣ Question 2: LC-MS 🧪 a) 💉 Sample introduction: Into the LC: the sample is dissolved in a mobile-phase-compatible solvent, centrifuged or filtered, and injected by an autosampler. A high-pressure pump pushes it through a column. Into the MS: the column eluent goes into an electrospray ionization (ESI) source. A high voltage makes charged droplets, the solvent evaporates, and gas-phase ions enter the vacuum of the instrument. b) 🔬 Properties used: LC uses hydrophobicity (reversed-phase), or size (SEC) or charge/pI (ion exchange) in other modes. MS uses the mass-to-charge ratio (m/z). c) 📊 What can be measured: intact mass, retention time, purity, sequence and PTMs (via MS/MS or digests), and quantity from the peak area. d) 🔦 Detection: ions hit a detector that converts each hit into an electrical pulse, and a digitizer records it. In a TOF, flight time is converted to m/z. The output is a mass spectrum plus a chromatogram, and software deconvolutes the charge states into the neutral mass. e) ⚠️ Limitations: quantitation needs standards, it can’t tell isomers apart by mass alone, and it is expensive and needs training. 3️⃣ Question 3: BioAccord (A) vs CDMS (E) ⚖️ 🅰️ BioAccord 🅴 CDMS (Charge Detection MS) a) ✨ What’s unique A plug-and-play LC-TOF with built-in LC and self-diagnostics, made for routine protein identification and mass (low–mid sensitivity) Measures one ion at a time, getting both m/z and charge (z), so it weighs megadalton, native particles directly (AAV, LNPs, viruses, large complexes) b) 📈 Output Mass spectrum (m/z vs intensity) with a charge-state envelope, TIC/XIC chromatograms (intensity vs time), and a deconvoluted neutral mass An m/z spectrum plus a true mass vs charge plot (one dot per ion), summed into a mass histogram of the species present c) 🧪 What I’d measure Aptamer product: exact mass of the 39-nt aptamer unit after RCA and XcmI cutting, plus shorter/longer strands (n−1/n+1). I could also check insulin (~5808 Da) for +1 Da deamidation, +16 Da oxidation or dimers after a temperature excursion RCA product: the mass distribution of the very long concatemers (average repeats per strand, and batch consistency). I could also look for heat-induced insulin aggregates d) 🧫 Sample format Denatured (acidic/organic mobile phase). Can be reduced (insulin A and B chains) or digested (to locate modifications). Oligos use an ion-pairing mobile phase. Needs filtered, desalted sample with no detergents or non-volatile salts, so I’d remove phi29, Mg²⁺ and dNTPs Native/folded in a volatile buffer like ammonium acetate (buffer exchange, no denaturant or digestion), very dilute so only one ion hits the detector at a time, and not filtered (aggregates are what I’m looking for) 4️⃣ Question 4: Validating my aptamer is made in the correct form 🧬✅ My project: a cell-free-made insulin-binding DNA aptamer (IGA3) for a disposable electrochemical cartridge that screens insulin after a cold-chain failure. My Week 2 design makes it in three steps:</description><generator>Hugo</generator><language>en</language><atom:link href="https://pages.htgaa.org/2026b/shaymaa-yakout/week-07-hw-mass-spec/index.xml" rel="self" type="application/rss+xml"/></channel></rss>