Week-09-HW-genetic-circuits

Homework Questions
Neuromorphic genetic circuits give us the ability to finely tune expression of an output as a function of 1 or more inputs (such as the input/output behavior of the single ERN circuit shown in the video above). One example of how this could be useful is classifying cancer cells from non-cancer cells, where the inputs are the expression of TNSF10 and TRPM1 and the output could be a killer molecule (Figure 1).

Question 1)Design a neuromorphic genetic circuit that successfully classifies uveal melanoma from healthy cells. Your design should include TNSF10 and TRPM1 as inputs (e.g., X1 and X2 from the video example) , neuromorphic genetic circuitry that classifies cancer from healthy cells (e.g., an ERN and ERN target), and a molecular output that can treat/cure this cancer (think of strategies to either kill or reprogram the cancer, simulate the immune system, etc). The available neuromorphic genetic parts can be found in this spreadsheet (ignore both of the marker columns for now): HTBAA 2026 Genetic Circuit Part Names. If using the NeuromorphicWizard to complete the homework, use this template to create your genetic circuit so you can use the Predict tab to check your circuit’s input/output behavior: HTBAA 2026 Genetic Circuit Design Template - you will need to specify an arbitrary marker for each input. Wizard tutorial.mp4 [AI use discouraged]

Input : TRPM1 (X2 ) ERN (Bias) TNSF 10( X1) output: killer protein(TNSF10)
Increasing translation rate of output:killer protein(TNSF10)
The positive element increases(X2), the decision boundary moves down.
With Bias:
Both inputs are high (X1 and X2) bias has a fixed value, output will also be high.( killer protein). This happens because X1 and X2 are both higher than the bias. Bias is negative.
In the case when X1 and X2 are low the output is low because both X1 and X2 are lower than the bias.
Only when X1 or X2 or combination of both are higehr than bias we get output(reprogramming function). This is called the high pass.
Low pass: The X1 And X2 are low and output is high.
The bias is positive and X1 and X2 are repressors so they are negative weights. The X1 and X2 are lower than the bias so the output is high. only when X1 and X2 in combiantion exceeds the bias will the output be low.
Two neurons would be required to create the dual region where the X1 and X2 would be positive weights in one neuron and negative weights in the other. the bias would also be positive and negative in the two neurons based on the positive and negative weights of inputs.
Bandpass: Three neurons would be required. X1 and X2 would be positive weights in one neuron and negative weights in the other, the bias would also be positive and negative in the two neurons based on the positive and negative weights of inputs. The output of this would be the input for the third neuron, which would have a negative weight and the bias would be positive. the output which is the negative weight if above the bias then the final output is low otherwise the output is high.




Question 2) Pick a disease that you think could be treated or cured with a cell therapy. Then, research whether there are distinct biological markers (ideally 2 or 3 markers) that distinguish a diseased state from a non-diseased state. It’s important that the levels of these markers are characterized beyond just high/low levels: Look for data that measure the exact levels of the markers you choose. Make an input/output scatterplot or similar graph that incorporates your markers and classifies whether that point is considered diseased or not. [AI use encouraged]
I choose Alzheimer’s disease. Distinct biomarkers are pt-tau217 and p-tau181 proteins high to very high in diseased state. Aβ42/40 biomarker is low in diseased state.This is in comparison to non’diseased state.
| Analytical Platform | Biomarker | Non-Diseased (Aβ− / Healthy Controls) | Diseased (Aβ+ / Alzheimer’s Disease) | Mean / Median Fold-Change |
|---|---|---|---|---|
| Fujirebio Lumipulse G (Chemiluminescence) | p-tau217 | 0.10 pg/mL (IQR: 0.08 – 0.12) | 0.36 pg/mL (IQR: 0.12 – 0.78) | 3.6× |
| Fujirebio Lumipulse G (Chemiluminescence) | p-tau181 | 1.10 pg/mL (IQR: 0.87 – 1.23) | 1.90 pg/mL (IQR: 1.18 – 2.79) | 1.7× |
| Quanterix Simoa (Cohort 1 — Mean ± SD) | p-tau217 | 0.34 ± 0.29 pg/mL | 1.98 ± 0.76 pg/mL | 5.8× |
| Quanterix Simoa (Cohort 1 — Mean ± SD) | p-tau181 | 2.14 ± 1.83 pg/mL | 4.41 ± 2.42 pg/mL | 2.1× |
| Quanterix Simoa (Cohort 2 — Mean ± SD) | p-tau217 | 0.41 ± 0.29 pg/mL | 1.29 ± 0.77 pg/mL | 3.1× |
| Quanterix Simoa (Cohort 2 — Mean ± SD) | p-tau181 | 2.30 ± 1.16 pg/mL | 4.43 ± 1.82 pg/mL | 1.9× |
| Meso Scale Discovery (MSD) (BioFINDER-2 — Median, Range) | p-tau217 | 2.81 pg/mL (0.50 – 36.0) | 7.36 pg/mL (0.70 – 21.4) | 2.6× |
| Meso Scale Discovery (MSD) (BioFINDER-2 — Median, Range) | p-tau181 | 7.90 pg/mL (1.10 – 24.8) | 13.10 pg/mL (3.70 – 57.4) | 1.7× |
- Fujirebio Lumipulse G DataValues: Non-diseased ($\text{A}\beta-$) vs. Diseased ($\text{A}\beta+$) median (IQR) of 0.10 (0.08–0.12) vs. 0.36 (0.12–0.78) $\text{pg/mL}$ for p-tau217, and 1.10 (0.87–1.23) vs. 1.90 (1.18–2.79) $\text{pg/mL}$ for p-tau181.
Source Study: Martínez-Dubarbie et al. (2025), “Diagnostic performance of plasma p-tau217 in a memory clinic cohort using the Lumipulse automated platform,” published in Alzheimer’s Research & Therapy (doi:10.1186/s13195-025-01719-5) 2. Quanterix Simoa Data (Cohorts 1 & 2)Values:Cohort 1 (Mean ± SD): 0.34 ± 0.29 vs. 1.98 ± 0.76 $\text{pg/mL}$ for p-tau217, and 2.14 ± 1.83 vs. 4.41 ± 2.42 $\text{pg/mL}$ for p-tau181.Cohort 2 (Mean ± SD): 0.41 ± 0.29 vs. 1.29 ± 0.77 $\text{pg/mL}$ for p-tau217, and 2.30 ± 1.16 vs. 4.43 ± 1.82 $\text{pg/mL}$ for p-tau181.
Source Study: Kwon et al. (2025), “Comparison of plasma p-tau217 and p-tau181 in predicting amyloid positivity and prognosis among Korean memory clinic patients,” published in Scientific Reports (doi:10.1038/s41598-025-90232-8).
- Meso Scale Discovery (MSD) Data (BioFINDER-2)Values: Non-diseased ($\text{A}\beta-$ CU) vs. Diseased ($\text{A}\beta+$ MCI) median (range) of 2.81 (0.50–36.0) vs. 7.36 (0.70–21.4) $\text{pg/mL}$ for p-tau217, and 7.90 (1.10–24.8) vs. 13.10 (3.70–57.4) $\text{pg/mL}$ for p-tau181.
Source Study: Pereira et al. (2021), “Plasma markers predict changes in amyloid, tau, atrophy and cognition in non-demented subjects,” published in Brain, Vol. 144, pp. 2826–2836 (Pereira et al., 2021).

What the figure shows
Panel A (raw values). p-tau181 is on the x-axis and p-tau217 on the y-axis, on log scales. Blue points are non-diseased and red points are diseased, with a different marker shape for each platform (Lumipulse, Simoa Cohort 1 and 2, MSD). Gray arrows run from each platform’s non-diseased point to its diseased point, so every platform shifts up and to the right. The platforms sit at very different absolute levels, for example MSD p-tau217 is 2.81 pg/mL in non-diseased vs. 0.10 on Lumipulse, so raw values can’t be compared across platforms.
Panel B (normalized classification). Each platform’s values are divided by its own non-diseased value, so all four non-diseased points land at (1×, 1×). The diseased points move to p-tau181 1.7 – 2.1× and p-tau217 2.6 – 5.8×. I shaded a “diseased” region where p-tau217 ≥ 2× and p-tau181 ≥ 1.5×. All four diseased points fall inside it and the non-diseased point falls outside.
Important limits to state
This is group-level data, not individual patients. Each point is a group median or mean, so the plot shows the shift between groups, not how well individual people are classified.
The 2× and 1.5× cutoffs are illustrative. I chose them to sit between the groups, so classifying these same four points correctly is circular, not a validation.
Overlap is large. In Panel A the error bars between non-diseased and diseased overlap on every platform. The MSD ranges, for example, are 0.50 – 36.0 vs. 0.70 – 21.4 for p-tau217, so a single MSD value in the overlap can’t be classified from this table alone. That is why the two-cutoff, intermediate-zone approach exists.
Finally, design a neuromorphic genetic circuit that incorporates sensing of your chosen markers, neuromorphic genetic circuitry that classifies disease vs. non-disease, and a molecular output that could treat/cure your disease of choice. [AI use discouraged]
I take two biomarkers as input and use a bias. The output would be reprogramming cells to iPSCs with OCT4, SOX2, KLF4, and c-MYC (or OSK). Correct the disease drivers with gene editing (for example, a risk mutation if one is known). Convert the iPSCs into neurons with a factor such as NGN2 (excitatory cortical neurons) or a defined differentiation protocol. The factor choice is from general knowledge, so verify it for your neuron type. Check that the new neurons meet the healthy marker ranges, then transplant.

Inputs are p tau 217 and p tau 181 (X1 and X2 respectively) for alzheimers disease. Output is reprogramming of cells to iPSCs. ERN is the bias here.X3 is the DNA for reprogramming genes.
Increasing translation rate of output: reprogramming cells.
In the first layer X1 and X2 are negative weights so expressed highly the bias is positive so sum of weights is Bias -X1-X2. In the second layer X1 and X2 are positive weights so expressed highly the bias is negative so sum of weights is (X1+X2)-Bias. This becomes input for 3rd layer and now it is negative weight and represses the positive weight X3.This along with the bias produce the output which is the reprogramming of cells.
In the case when X1 and X2 are low the output is low because both X1 and X2 are lower than the bias.
Only when X1 or X2 or combination of both are higehr than bias we get output(reprogramming function). This is called the high pass.
Low pass: The X1 And X2 are low and output is high.
The bias is positive and X1 and X2 are repressors so they are negative weights. The X1 and X2 are lower than the bias so the output is high. only when X1 and X2 in combiantion exceeds the bias will the output be low.
Two neurons would be required to create the dual region where the X1 and X2 would be positive weights in one neuron and negative weights in the other. the bias would also be positive and negative in the two neurons based on the positive and negative weights of inputs.
Bandpass: Three neurons would be required. X1 and X2 would be positive weights in one neuron and negative weights in the other, the bias would also be positive and negative in the two neurons based on the positive and negative weights of inputs. The output of this would be the input for the third neuron, which would have a negative weight and the bias would be positive. the output which is the negative weight if above the bias then the final output is low otherwise the output is high.
Question 3) So far we’ve only focused on how neuromorphic genetic circuits can be used in medicine. Choose a non-medical application that uses a neuromorphic genetic circuit of your own design. Like the previous questions, specify what your circuit design senses, the neuromorphic genetic circuitry, and the output of your circuit. [AI use discouraged]
The Idea
A yeast that makes oil, checks its own recipe as it goes, and nudges it toward olive oil’s balance of fats.
The fats involved
Olive oil is mostly oleic acid (about 55 to 83%). Yeast naturally makes a different mix, usually with too much of two other types:
Saturated fat (too much makes the oil waxy and not olive-like) Linoleic acid (too much makes the oil spoil faster and doesn’t match olive oil)
The goal
Olive oil is defined by its fat profile, roughly: oleic acid 55 – 83% (high), palmitic 7.5 – 20%, linoleic 2.5 – 21%, and stearic under 5% (low). Yeast naturally makes a mix that can drift away from this, usually with too much saturated fat or too much linoleic acid. The circuit keeps the mix in the olive range.
| Input | Decision | Output |
|---|---|---|
| Too much saturated fat | Push oleic up | OLE1 on |
| Too much linoleic | Hold oleic steady | FAD2 off |
| Nitrogen still high | Not time yet | Circuit stays off |
| Fats already in range | Nothing to fix | No change |
Genetic circuit

Inputs: Mga2 (senses saturated fat) and Ire1 (senses abnormal lipid in Endoplasmic reticulum-backup signal). Output: more oleic acid
Bias (ERN)
Increase translation rate of output:OLE1 output
The positive element increases(X1 and X2), the decision boundary moves down.
With Bias:
Both inputs are high (X1 and X2) bias has a fixed value, output will also be high.( OLE1 output). This happens because X1 and X2 are both higher than the bias. Bias is negative.
In the case when X1 and X2 are low the output is low because both X1 and X2 are lower than the bias.
Only when X1 or X2 or combination of both are higehr than bias we get output(reprogramming function). This is called the high pass.
Low pass: The X1 And X2 are low and output is high.
The bias is positive and X1 and X2 are repressors so they are negative weights. The X1 and X2 are lower than the bias so the output is high. only when X1 and X2 in combiantion exceeds the bias will the output be low.
Two neurons would be required to create the dual region where the X1 and X2 would be positive weights in one neuron and negative weights in the other. the bias would also be positive and negative in the two neurons based on the positive and negative weights of inputs.
Bandpass: Three neurons would be required. X1 and X2 would be positive weights in one neuron and negative weights in the other, the bias would also be positive and negative in the two neurons based on the positive and negative weights of inputs. The output of this would be the input for the third neuron, which would have a negative weight and the bias would be positive. the output which is the negative weight if above the bias then the final output is low otherwise the output is high.
Example: what happens in the tank
Early growth, nitrogen plentiful. The circuit is off, and the yeast just multiplies.
Oil-making phase, fat mix drifts saturated. OLE1 turns up, so more saturated fat becomes oleic.
Oil-making phase, too much linoleic. FAD2 is repressed, so less oleic is turned into linoleic.
Fat mix lands in the olive range. The circuit stays quiet.
The result
Oil with roughly 70 to 80% oleic acid, which is within the range expected of olive oil. A lab test (GC-FID) confirms the fat profile.
Mammalian Lab Circuit
Creating your genetic circuit
Make a copy of this template (template link) and modify it to describe your genetic circuit.
Key info: The “Concentration” column will always be 50 ng/μL and the sum of all numbers in the “DNA wanted (ng)” column should never exceed 800 ng. Follow the naming conventions for the “Contents” column using this list of part names: part name link. This is important for simulating your circuit’s behavior.






AI prompts used
can you explain olive oil example in a similar way?
TNSF10 and TRPM1 what are these markers
does tnsf10 repress or activate trpm1
so by the introduction i see the relation as in myeloma the input TRPM1 should be low in cancerous cell so that the tnsf10 is edpressed and binds to the cancer cells causing apoptosis
search data
how are these markers controlled by case ern or cys4 ern
Look for data that measure the exact levels of the markers you choose.
cite published data and plot graphs
its uveal myeloma where these two are inputsso by the introduction i see the relation as in myeloma the input TRPM1 should be low in cancerous cell so that the tnsf10 is edpressed and binds to the cancer cells causing apoptosis explain so that i can create my circuit
can neuromorphic circuit be used in this biomanufacture of olive oil equivalent