1)For one of the analytical tools you have worked with thus far (e.g. plate readers, gel electrophoresis), describe:
Tool: UV-Vis Spectrophotometer
How is the sample introduced?
- Liquid solution in a cuvette.
What physiochemical property is being leveraged to study the sample with this tool?
- Optical properties.
What does this allow you to measure?
- The absorption or transmission of electromagnetic radiation (light) at a certain wavelength
- Eg. the optical density (OD) of a culture at a certain wavelength, and then you can use that as a reference to track the growth. You can also plot a graph, of OD at different wavelengths, to observe if it is producing any peaks at any weavelengths, such as the different peaks indicating different pigments (eg. chlorophyll, carotenoids, phycocyanin peaks in a cyanobacteria)
How is the output signal detected?
- Itβs detected by a photodetector, and there are different types of photodetectors: photovoltaic cells, photo tube / photocell, or a photomultiplier tube (the combination of a photodiode and an electron-multiplying amplifier).
What limitations does the tool have?
- It is limited to liquid samples, and samples must be translucent. The sample also has to be homogenous as it only reads the sample at a specific point, and it will also read contaminants, air bubbles or dust. It is also not suitable for analyzing complex mixtures where the wavelengths of different molecules overlap.
2) For a liquid chromatography mass spectrometry (LC-MS) instrument:
How is the sample introduced into the LC? Into the MS?
- It is introduced into the LC as a liquid sample, by injection, and then through electrospray ionization into MS.
What physiochemical properties are being leveraged to study the sample with this tool?
- Hydrophobicity or size of compounds for LC, and mass (mass to charge ratios) for MS.
What does this allow you to measure?
- Molecular weight, primary structure of proteins
How is the output signal detected?
- Ions are passed through a conical tube, where the insides are coated with materials rich in electrons. When the ion hits, it causes a release of electrons that gets amplified as it passes through the tube, and outputs as a digital signal.
What limitations does the tool have?
- It gives very limited understanding of the secondary and tertiary structures of the proteins that you are measuring. It is also relatively expensive and time consuming in the sense that it is a multi-step process.